Status mismatch
This permit has 9 inspection(s) on record but its status is IN REVIEW — not ISSUED. Inspections should only be performed on issued permits. Update the status if this permit has been issued.
Permit Timeline
⬤ In Review
8/21/2026
Issued
MOISTURE BARRIER
05/19/2026
PASS
MOISTURE BARRIER
06/17/2026
PASS
ROUGH BUILDING
08/03/2026
C&R
ROUGH BUILDING
08/14/2026
C&R
ROUGH BUILDING
08/24/2026
PASS
PLUMBING
08/27/2026
PASS
INSULATION
08/27/2026
PASS
POOL BASKET
09/03/2026
PASS
+1 More
Permit Finaled
Certificate Issued
Project Information
Edmunds #
—
MC #
MC2026-464
Issued Date
—
Finaled Date
—
Owner
—
Owner Address
—
Contractor
—
Project Type
SWIMMING POOL
Description
PUBLIC SWIMMING POOL - RECTANGULAR OUTDOOR GUNITE POOL, 74' X 28', MINIMUM DEPTH 2'-9", MAXIMUM DEPTH 5'-0", AREA 2,072 SQ. FT., VOLUME 52,037 GALLONS, AT THE PRESERVE AT FOXRUN
Technical Details
Construction Type
—
Occupancy Group
—
Occupant Load
—
Square Footage
2072
Zoning
—
Sprinklers
—
APN
—
Limitations
—
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 09/03/2026 | POOL BASKET | Tyler Adams | PASS | — |
| 09/03/2026 | ROUGH ELE BON P | Tyler Adams | PASS | — |
| 08/27/2026 | PLUMBING | Tyler Adams | PASS | — |
| 08/27/2026 | INSULATION | Tyler Adams | PASS | — |
| 08/24/2026 | ROUGH BUILDING | Tyler Adams | PASS | — |
| 08/14/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - MISSING FOUR DOUBLE HANGERS IN HALLWAY AROUND ATTIC PULL DOWN - NAIL ON ROUND BOXES NEED TO BE SECURED WITH THE NAILS ATTACHED TO THE BOX NOT SCREWS THROUGH THE BOX - FLOOR OUTLET BOXES ARE NOT CEMENTED TO CONDUIT, COUPLINGS ARE JUST SLID OVER BOXES |
| 08/03/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - fir out wall at low volt panel to maintain r value? Or relocate to an uninsulated wall - nail on round boxes in ceiling are installed with sheetrock rock screws through the box, the need to be installed as designed - bond all metal boxes - pancake boxes are over box fill with two cable penetrations - insulate all 3/4 hot waterlines - fir out walls at electrical panels to maintain r value - sheathing behind left electrical panel not fastened to a stud at all - KO seal needed in 2” insider opening bottom of right panel - bond to UFER - bond to gas line - disconnect in back left mechanical closet is a surface mounted disconnect not a recessed mounted disconnect - stub out for urinal needs to be sweated to bracket to keep it from moving in the bracket and causing pin holes down the line - missing nail guard over waterline to middle toilet in men’s restroom - missing four double hangers in ceiling of hallway to restrooms - connections at floor outlets need to be made with appropriate fittings not seal tite and tape |
| 06/17/2026 | MOISTURE BARRIER | Tyler Adams | PASS | — |
| 05/19/2026 | MOISTURE BARRIER | Tyler Adams | PASS | — |