4123 JOHNSTONVILLE RD

ISSUED

Permit Timeline

In Review 8/18/2026
Issued 8/20/2026
T-POLE 09/15/2026 PASS
UNDERSLAB PLUMB 09/15/2026 C&R
UNDERSLAB PLUMB 09/17/2026 PASS
WALL SHEATHING 10/19/2026 PASS
MOISTURE BARRIE 10/23/2026 PASS
ROUGH BUILDING 10/23/2026 PASS
Permit Finaled
Certificate Issued

Project Information

Edmunds #

—

MC #

MC2026-453

Issued Date

8/20/2026

Finaled Date

—

Owner

CHRIS GIBSON HOMES

Owner Address

LOT 11 BUTTERNUT

Contractor

CHRIS GIBSON HOMES

Project Type

—

Description

NEW SFR

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

3080

Zoning

A-R

Sprinklers

NO

APN

039A037

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
10/23/2026 MOISTURE BARRIE Tyler Adams PASS —
10/23/2026 ROUGH BUILDING Tyler Adams PASS —
10/19/2026 WALL SHEATHING Tyler Adams PASS —
09/17/2026 UNDERSLAB PLUMB Tyler Adams PASS —
09/15/2026 T-POLE Tyler Adams PASS —
09/15/2026 UNDERSLAB PLUMB Tyler Adams CORRECT AND RECALL - SLEEVE OVER DRAIN THROUGH FOUNDATION NEEDS TO BE SIX INCH, CODE REQUIRES SLEEVES BE TWO NOMINAL PIPE SIZES LARGER THAN PIPE BEING SLEEVED - STAMPED PLANS NEED TO BE ON SITE - HOUSE HAS BEEN FORMED UP MIRRORED FROM THE APPROVED PLANS, RESUBMIT PLANS SHOWING THE MIRRORED ORIENTATION

Schedule Inspection

Quick Reference

Edmunds #

— (pending)

MC #

MC2026-453

Quick Add Inspection
Generate CO
Generate CC