Permit Timeline
In Review
8/17/2026
Issued
UNDERSLAB PLUMBING
08/24/2026
PASS
FOUNDATION
08/31/2026
C&P
SLAB GRADE
09/22/2026
PASS
WALL SHEATHING
09/22/2026
C&P
MOISTURE BARRIER
10/16/2026
PASS
ROUGH BUILDING
10/16/2026
C&R
Permit Finaled
Certificate Issued
Project Information
Edmunds #
—
MC #
MC2026-450
Issued Date
—
Finaled Date
—
Owner
B SQUARED HOMES LLC
Owner Address
76 VAUGHN SCHOOL RD, GRIFFIN, GA 30223
Contractor
MEREDITH HOMES INC
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
SFR
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
3351
Zoning
A-R
Sprinklers
NO
APN
062032-H
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 10/16/2026 | MOISTURE BARRIER | Tyler Adams | PASS | — |
| 10/16/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - repair blown out concrete in garage where plumbing was moved - plumber has over bored 15 2x10 floor joist, max diameter allowed is 3 inches holes bored are 3.5-4 inches in diameter, and many are with in 2 inches of the bottom of the joist - draft block over panel - insulate waterlines in garage ceiling - missing insulation and vapor barrier behind tub/shower inserts on exterior walls - frame mechanical chases - missing hurricane ties on some rafter connections - no water on tubs and drains |
| 09/22/2026 | SLAB GRADE | Tyler Adams | PASS | — |
| 09/22/2026 | WALL SHEATHING | Tyler Adams | CORRECT AND PROCEED | PROVIDE ON SITE RESTROOM FACILITIES THROUGH ALL PHASES OF CONSTRUCTION |
| 08/31/2026 | FOUNDATION | Tyler Adams | CORRECT AND PROCEED | - STUB UP UFER ROD FROM PERIMETER FOOTINg |
| 08/24/2026 | UNDERSLAB PLUMBING | Tyler Adams | PASS | — |