115 HEIGHTS AVE

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 8/3/2026
Issued 8/6/2026
T-POLE 08/20/2026 PASS
UNDERSLAB PLUMB 08/25/2026 C&R
UNDERSLAB PLUMB 08/26/2026 PASS
FOUNDATION 08/28/2026 PASS
WALL SHEATHING 10/05/2026 C&R
WALL SHEATHING 10/07/2026 PASS
MOISTURE BARRIER 10/09/2026 PASS
GAS TEST 10/22/2026 PASS
+1 More
Permit Finaled
Certificate Issued

Project Information

Edmunds #

—

MC #

MC2026-425

Issued Date

8/6/2026

Finaled Date

—

Owner

REYNOLDS HOMES LLC DBA NEW LEAF HOMES

Owner Address

1001 VILLAGE PARK DR SUITE 103, GREENSBORO, GA 30642

Contractor

NEW LEAF HOMES

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

DOCKSIDE 4 BEDROOM, ELEVATION B - SINGLE-STORY HOUSE WITH GABLED ROOFS, DORMERS, BRICK VENEER, AND LAP SIDING

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

3399

Zoning

R-1

Sprinklers

NO

APN

026R008

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
10/22/2026 GAS TEST Tyler Adams PASS —
10/22/2026 ROUGH BUILDING Tyler Adams CORRECT AND PROCEED - HOOD EXHAUST DUT BEOKEN LOOSE IN ATTIC CEILING
10/09/2026 MOISTURE BARRIER Tyler Adams PASS —
10/07/2026 WALL SHEATHING Tyler Adams PASS —
10/05/2026 WALL SHEATHING Tyler Adams CORRECT AND RECALL 3X3 FASTENING GRID NOT MET AT GARAGE POST CORNERS
08/28/2026 FOUNDATION Tyler Adams PASS —
08/26/2026 UNDERSLAB PLUMB Tyler Adams PASS —
08/25/2026 UNDERSLAB PLUMB Tyler Adams CORRECT AND RECALL - SLEEVE OVER BUILDING DRAIN PASS THROUGH/UNDER FOUNDATION IS REQUIRED TO BE 2 NOMINAL PIPE SIZES LARGER THAN THE PIPE BEING SLEEVED, 6 IN PIPE NEEDED
08/20/2026 T-POLE Kyle Golberg PASS —

Schedule Inspection

Quick Reference

Edmunds #

— (pending)

MC #

MC2026-425

Quick Add Inspection
Generate CO
Generate CC