490 INDIAN SPRINGS DR

FINALED
ACCESSORY STRUCTURE

Permit Timeline

In Review 7/13/2026
Issued 7/21/2026
FOOTING 07/29/2026 PASS
PLUMBING 07/29/2026 PASS
ELECTRICAL 09/08/2026 C&R
ELECTRICAL 09/16/2026 PASS
FINAL 09/18/2026 PASS
Permit Finaled 9/18/2026
Certificate Issued 10/26/2026

Project Information

Edmunds #

P-480726

MC #

MC2026-412

Issued Date

7/21/2026

Finaled Date

9/18/2026

Owner

HARLEY DAVIS

Owner Address

490 INDIAN SPRINGS DR, FORSYTH, GA

Contractor

LONGHORN STEEL STRUCTURES

Project Type

ACCESSORY STRUCTURE

Description

PARTIALLY ENCLOSED GABLE END METAL BUILDING, MAXIMUM 0' TO <30' WIDE X <20' MAXIMUM EVE HEIGHT (BOX FRAME), UP TO 155 M.P.H. WIND ZONE – 35 P.S.F. SNOW LOAD, WITH ROLL-UP GARAGE DOOR AND WALK-THROUGH ENTRY DOOR

Technical Details

Construction Type

II-B

Occupancy Group

U

Occupant Load

N/A

Square Footage

1176

Zoning

R

Sprinklers

NO

APN

F14009

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
09/18/2026 FINAL Tyler Adams PASS —
09/16/2026 ELECTRICAL Tyler Adams PASS —
09/08/2026 ELECTRICAL Tyler Adams CORRECT AND RECALL - BOND ALL JUNCTION BOXES AND LIGHT BOXES - SWITCH BOXES WITH PLASTER RINGS WILL NEED TO HAVE A RS TYPER COVER INSTALLED OR THE WALLS CLAD AND A SWITCH COVER INSTALLED - PLASTIC OUTLET BOXES ARE NOT LISTED TO BE USED WITH MC CABLE - ATTACHMENT FOR THE SERVICE MAST NEEDS TO BE SECURED TO A STRUCTURAL MEMBER OF THE BUILDING, CURRENTLY SECURED TO CONDUIT RISER THAT IS SECURED ONLY TO THE METAL SIDING
07/29/2026 FOOTING Tyler Adams PASS —
07/29/2026 PLUMBING Tyler Adams PASS —

Schedule Inspection

Quick Reference

Edmunds #

P-480726

MC #

MC2026-412

Quick Add Inspection