340 FAULKNER RD

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Inspector Notes

CHECK FOR ACCESS PANEL OVER UFER AT FINAL

Inspector Notes

Visible to inspectors on every inspection request. Never printed on reports.

Permit Timeline

In Review 6/22/2026
Issued 6/25/2026
UNDERSLAB PLUMBING 07/23/2026 PASS
FOOTING 07/29/2026 PASS
WALL SHEATHING 08/24/2026 C&R
WALL SHEATHING 08/27/2026 PASS
COMBO ROUGH 08/27/2026 C&R
ROUGH BUILDING 09/08/2026 C&P
ROUGH BUILDING 09/09/2026 PASS
MOISTURE BARRIER 09/09/2026 PASS
+3 More
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-710626

MC #

MC2026-384

Issued Date

6/25/2026

Finaled Date

—

Owner

LARRY CARDER

Owner Address

340 FAULKNER RD, JACKSON, GA 30233

Contractor

LARRY CARDEN

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

MODERN SINGLE-STORY RESIDENTIAL BUILDING WITH MONO-SLOPE (SHED) ROOF, STANDING SEAM METAL ROOFING, VERTICAL SIDING, LARGE QUAD SLIDER WINDOWS, AND GARAGE DOORS

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

1,456

Zoning

A-R

Sprinklers

NO

APN

036 016

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
10/26/2026 PERMANENT SERVI Tyler Adams PASS —
10/19/2026 PERMANENT SERVI Tyler Adams CANCEL —
09/15/2026 INSULATION Tyler Adams PASS —
09/09/2026 ROUGH BUILDING Tyler Adams PASS —
09/09/2026 MOISTURE BARRIER Tyler Adams PASS —
09/08/2026 ROUGH BUILDING Tyler Adams CORRECT AND PROCEED - extend portal straps at garage opening facing lake to the top plate - UFER connection needs to be accessible with a hand hole - tape joints in zip system sheathing
08/27/2026 WALL SHEATHING Tyler Adams PASS —
08/27/2026 COMBO ROUGH Tyler Adams CORRECT AND RECALL - NEED SILL PLATE ANCHORS WITH 2X2” SQUARE WASHERS WITH IN 12 INCHES BOTH SIDE OF GARAGE POSTS - INSULATE ALL WATERLINES IN GARAGE WALLS - PLUMBING IN HALF BATH VENT IS NOT EXERTING TO EXTERIOR - ELECTRICAL IS NOT BONDED TO GET GROUND IN GARAGE - PORTAL STRAPS ON BACK GARAGE DOOR FACING POND NEEDS TO EXTEND TO TOP PLATE - INSULATE ALL 3/4 HOT WATERLINES - GARAGE CANNOT SHARE DUCT WORK FROM LIVING SPACE, A SEPARATE SYSTEM IS REQUIRED - NO PRESSURE ON WATERLINES - VENT FOR WASHER STAND PIPE DOES NOT EXTEND TO EXTERIOR - SILL PLATE ANCHORS REQUIRED WITH IN 12” OF ALL BREAKS AND JOINTS IN EXTERIOR SILL PLATE - SEAL OFF FIREPLACE CHASE - NO MASTIC INSIDE AC REGISTER BOOTS - NEUTRAL AND GROUND HAVE NOT BEEN LANDED IN ELECTRICAL PANEL - INSULATION REQUIRE BEHIND ELECTRICAL PANEL IF GARAGE WALLS WILL BE INSULATED - CONNECTORS AT ELECTRICAL PANEL ARE OVER FULL UL LISTING DOES NOT ALLOW THE NUMBER OF THE COMBINATION OF CABLES FITTED BENEATH CONNECTORS - INSTALL SEAM TAPE ON ZIP SYSTEM AND WINDOWS
08/24/2026 WALL SHEATHING Tyler Adams CORRECT AND RECALL - 3X3 FASTENING GRID NOT MET AT GARAGE POST CORNERS SEE ATTACHED DIAGRAM HIGHLIGHTED SECTION - NAIL OFF TO BOTH STUDS BENEATH GARAGE HEADER 3" ON CENTER SEE ATTACHED DIAGRAM HIGHLIGHTED SECTION - NAIL OFF TO BLOCKING AT HORIZONTAL SHEATHING JOINTS 6" ON CENTEr
07/29/2026 FOOTING Tyler Adams PASS —
07/23/2026 UNDERSLAB PLUMBING Tyler Adams PASS —