Inspector Notes
CHECK FOR ACCESS PANEL OVER UFER AT FINAL
Permit Timeline
In Review
6/22/2026
Issued
6/25/2026
UNDERSLAB PLUMBING
07/23/2026
PASS
FOOTING
07/29/2026
PASS
WALL SHEATHING
08/24/2026
C&R
WALL SHEATHING
08/27/2026
PASS
COMBO ROUGH
08/27/2026
C&R
ROUGH BUILDING
09/08/2026
C&P
ROUGH BUILDING
09/09/2026
PASS
MOISTURE BARRIER
09/09/2026
PASS
+3 More
Permit Finaled
Certificate Issued
Project Information
Edmunds #
P-710626
MC #
MC2026-384
Issued Date
6/25/2026
Finaled Date
—
Owner
LARRY CARDER
Owner Address
340 FAULKNER RD, JACKSON, GA 30233
Contractor
LARRY CARDEN
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
MODERN SINGLE-STORY RESIDENTIAL BUILDING WITH MONO-SLOPE (SHED) ROOF, STANDING SEAM METAL ROOFING, VERTICAL SIDING, LARGE QUAD SLIDER WINDOWS, AND GARAGE DOORS
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
1,456
Zoning
A-R
Sprinklers
NO
APN
036 016
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 10/26/2026 | PERMANENT SERVI | Tyler Adams | PASS | — |
| 10/19/2026 | PERMANENT SERVI | Tyler Adams | CANCEL | — |
| 09/15/2026 | INSULATION | Tyler Adams | PASS | — |
| 09/09/2026 | ROUGH BUILDING | Tyler Adams | PASS | — |
| 09/09/2026 | MOISTURE BARRIER | Tyler Adams | PASS | — |
| 09/08/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND PROCEED | - extend portal straps at garage opening facing lake to the top plate - UFER connection needs to be accessible with a hand hole - tape joints in zip system sheathing |
| 08/27/2026 | WALL SHEATHING | Tyler Adams | PASS | — |
| 08/27/2026 | COMBO ROUGH | Tyler Adams | CORRECT AND RECALL | - NEED SILL PLATE ANCHORS WITH 2X2” SQUARE WASHERS WITH IN 12 INCHES BOTH SIDE OF GARAGE POSTS - INSULATE ALL WATERLINES IN GARAGE WALLS - PLUMBING IN HALF BATH VENT IS NOT EXERTING TO EXTERIOR - ELECTRICAL IS NOT BONDED TO GET GROUND IN GARAGE - PORTAL STRAPS ON BACK GARAGE DOOR FACING POND NEEDS TO EXTEND TO TOP PLATE - INSULATE ALL 3/4 HOT WATERLINES - GARAGE CANNOT SHARE DUCT WORK FROM LIVING SPACE, A SEPARATE SYSTEM IS REQUIRED - NO PRESSURE ON WATERLINES - VENT FOR WASHER STAND PIPE DOES NOT EXTEND TO EXTERIOR - SILL PLATE ANCHORS REQUIRED WITH IN 12” OF ALL BREAKS AND JOINTS IN EXTERIOR SILL PLATE - SEAL OFF FIREPLACE CHASE - NO MASTIC INSIDE AC REGISTER BOOTS - NEUTRAL AND GROUND HAVE NOT BEEN LANDED IN ELECTRICAL PANEL - INSULATION REQUIRE BEHIND ELECTRICAL PANEL IF GARAGE WALLS WILL BE INSULATED - CONNECTORS AT ELECTRICAL PANEL ARE OVER FULL UL LISTING DOES NOT ALLOW THE NUMBER OF THE COMBINATION OF CABLES FITTED BENEATH CONNECTORS - INSTALL SEAM TAPE ON ZIP SYSTEM AND WINDOWS |
| 08/24/2026 | WALL SHEATHING | Tyler Adams | CORRECT AND RECALL | - 3X3 FASTENING GRID NOT MET AT GARAGE POST CORNERS SEE ATTACHED DIAGRAM HIGHLIGHTED SECTION - NAIL OFF TO BOTH STUDS BENEATH GARAGE HEADER 3" ON CENTER SEE ATTACHED DIAGRAM HIGHLIGHTED SECTION - NAIL OFF TO BLOCKING AT HORIZONTAL SHEATHING JOINTS 6" ON CENTEr |
| 07/29/2026 | FOOTING | Tyler Adams | PASS | — |
| 07/23/2026 | UNDERSLAB PLUMBING | Tyler Adams | PASS | — |