86 W MAIN ST

IN REVIEW

Status mismatch

This permit has 2 inspection(s) on record but its status is IN REVIEW — not ISSUED. Inspections should only be performed on issued permits. Update the status if this permit has been issued.

Permit Timeline

⬤ In Review 6/22/2026
Issued
FRAMING ROUGH 07/14/2026 C&R
MOISTURE BARRIER 8/11/2026 PASS
Permit Finaled
Certificate Issued

Project Information

Edmunds #

—

MC #

MC2026-383

Issued Date

—

Finaled Date

—

Owner

MILTON HEARD

Owner Address

295 COUNTRY CLUB RD MACON

Contractor

IVEY BLDS

Project Type

—

Description

CHURCH/HALL ADDITION INCLUDING PEWS, 4X9 STAGE, HVAC, CATHEDRAL RIDGE, SCONCES, CONCRETE PORCH, RAMP, AND 24X25 OPEN CARPORT

Technical Details

Construction Type

—

Occupancy Group

—

Occupant Load

—

Square Footage

—

Zoning

—

Sprinklers

—

APN

—

Limitations

—

Inspection History

Date Type Inspector Result Notes
8/11/2026 MOISTURE BARRIER TYLER ADAMS PASS —
07/14/2026 FRAMING ROUGH Tyler Adams CORRECT AND RECALL - 3x3 nail grid not met at garage posts corners on sheathing - 1000 lb straps needed from top plate to below garage headers - sill plate anchors needed with in 12 inches of any breaks or joints in exterior sill plate, and every six feet in between - nail off to both studs on garage posts every 2 inches - plumbing and electrical not roughed

Schedule Inspection

This permit is IN REVIEW, not ISSUED. You can still schedule, but verify the permit status is correct first.

Quick Reference

Edmunds #

— (pending)

MC #

MC2026-383

Quick Add Inspection
Generate CO
Generate CC