2806 BOXANKLE RD

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 6/15/2026
Issued 06/18/2026
UNDERSLAB PLUMB 06/30/2026 PASS
FOUNDATION 07/09/2026 PASS
WALL SHEATHING 07/31/2026 PASS
ROUGH BUILDING 08/10/2026 C&R
MOISTURE BARRIER 08/10/2026 CANCE
MOISTURE BARRIER 08/12/2026 PASS
ROUGH BUILDING 08/12/2026 PASS
INSULATION 08/14/2026 C&P
+2 More
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-570626

MC #

MC2026-378

Issued Date

06/18/2026

Finaled Date

—

Owner

BURNETT PROPERTIES LLC

Owner Address

P.O BOX 1274, FORSYTH, GA 31029

Contractor

BURNETT BUILDING LLC

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW CONSTRUCTION

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

2,560

Zoning

A-R

Sprinklers

NO

APN

026 039

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
10/22/2026 PERMANENT SERVI Tyler Adams PASS —
10/20/2026 PERMANENT SERVI Tyler Adams CORRECT AND RECALL PLANS HAVE NOT BEEN RESUBMITTED AND APPROVED AS REQUESTED ON 8-14 INSPECTIONS HELd
08/14/2026 INSULATION Tyler Adams CORRECT AND PROCEED - APPROVED PLANS SHOW AN ENCLOSED GARAGE NOT AN OPEN CARPORT, APPROVED PLANS ALSO SHOW THE HOUSE ORIENTED WITH GARAGE ON THE LEFT SIDE - ALTER PLANS TO SHOW CHANGES MADE AND THE ORIENTATION AS BUILT AND RESUBMIt
08/12/2026 MOISTURE BARRIER Tyler Adams PASS —
08/12/2026 ROUGH BUILDING Tyler Adams PASS —
08/10/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL - STUD SHOE NEEDED OVER DRAIN ARM TO WASHING MACHINE STANDPIPE - SILL PLATE ANCHOR NEEDED AT BREAK BY STUB UP FOR WASHING MACHINE STANDPIPE PIPE, LEFT SIDE OF BREAK - ADD BOARD OVER PANEL TO SECURE CABLES TO - REMOVE BOND SCREW FROM PANEL - MAKE UP SERVICE CABLES IN PANEL - CABLE NOT PULLED TO ISLAND - HANGERS NEEDED AT ATTIC PULL DOWN - WINDOWS NOT INSTALLED - SMOKE DETECTOR TO CLOSE TO BATHROOM OUTSIDE OF SECONDARY BEDROOMS - SECURE SERVICE CABLE AND GROUND WIRE IN EXTERIOR WALL AT METER STUB OUT - BOND ALL METAL BOXES
08/10/2026 MOISTURE BARRIER Tyler Adams CANCEL —
07/31/2026 WALL SHEATHING Tyler Adams PASS —
07/09/2026 FOUNDATION Tyler Adams PASS —
06/30/2026 UNDERSLAB PLUMB Tyler Adams PASS —

Schedule Inspection

Quick Reference

Edmunds #

P-570626

MC #

MC2026-378

Quick Add Inspection
Generate CO
Generate CC