753 HOPEWELL RD

FINALED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 4/30/2026
Issued 06/09/2026
UNDERSLAB PLUMBING 05/15/2026 C&R
UNDERSLAB PLUMBING 05/18/2026 PASS
SLAB ON GRADE 05/19/2026 PASS
SHEATHING 06/01/2026 PASS
MOISTURE BARRIER 06/03/2026 PASS
COMBO ROUGH 06/09/2026 C&P
MOISTURE BARRIER 06/09/2026 C&P
COMBO ROUGH 06/12/2026 PASS
+6 More
Permit Finaled 9/25/2026
Certificate Issued 10/26/2026

Project Information

Edmunds #

P-240526

MC #

MC2026-370

Issued Date

06/09/2026

Finaled Date

9/25/2026

Owner

TRADEMARK QUAILTY HOMES

Owner Address

P.O 926, GREENVILLE, GA 30222

Contractor

TRADEMARK QUAILTY HOMES

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

4618

Zoning

A-R

Sprinklers

NO

APN

031 022A

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
09/25/2026 FINAL Tyler Adams PASS —
09/18/2026 FINAL Tyler Adams CORRECT AND RECALL - pipe condensate drain away from foundation - screen covers needed on all exterior vent terminations other than dryer vent - vent hood not connected - outlets in dining room have no power - empty outlet box overhead in second floor bedroom ceiling - need to see passing blower door test
07/30/2026 PERMANENT SERVICE Tyler Adams PASS —
07/23/2026 PERMANENT SERVICE Tyler Adams CORRECT AND RECALL - fill empty breaker space in meter panel - missing two machine screws in dead front at meter panel - safe off loose wires in meter panel or land on breakers
06/18/2026 INSULATION Tyler Adams PASS —
06/17/2026 INSULATION Tyler Adams CANCEL —
06/12/2026 COMBO ROUGH Tyler Adams PASS —
06/09/2026 COMBO ROUGH Tyler Adams CORRECT AND PROCEED - house wrap needs to be over lapped and taped front left corner of house by garage - secure cable at dryer outlet - missing window right of fireplace - top chord of TGI floor joist drilled in ceiling of master bedroom by smoke detector - missing vapor barrier and insulation behind tub inserts on exterior walls -
06/09/2026 MOISTURE BARRIER Tyler Adams CORRECT AND PROCEED MISSING WINDOW FRONT RIGHT CORNER NEEDS TO OVERLAP AND BE TAPED
06/03/2026 MOISTURE BARRIER Tyler Adams PASS —
06/01/2026 SHEATHING Tyler Adams PASS —
05/19/2026 SLAB ON GRADE Tyler Adams PASS —
05/18/2026 UNDERSLAB PLUMBING Tyler Adams PASS —
05/15/2026 UNDERSLAB PLUMBING Tyler Adams CORRECT AND RECALL NO TEST ON DRAINS AT TIME OF INSPECTION