Permit Timeline
In Review
5/20/2026
Issued
FOOTING
06/25/2026
PASS
GARAGE SLAB
07/17/2026
PASS
WALL SHEATHING
08/06/2026
C&R
ROUGH BUILDING
08/06/2026
CANCE
MOISTURE BARRIE
09/15/2026
PASS
SHEATHING
09/15/2026
PASS
ROUGH BUILDING
09/18/2026
C&P
INSULATION
09/25/2026
CANCE
+2 More
Permit Finaled
Certificate Issued
Project Information
Edmunds #
P-160626
MC #
MC2026-361
Issued Date
—
Finaled Date
—
Owner
AMBER YARBROUGH
Owner Address
219 BUFORD PL, MACON, GA 31024
Contractor
HAMRICK CONSTRUCTION, LLC
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW CONSTRUCTION
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
2,921
Zoning
R-1
Sprinklers
NO
APN
113 056
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 9/28/2026 | INSULATION | JIM MCLAUGHLIN | PASS | — |
| 09/29/2026 | INSULATION | Jim McLaughlin | PASS | — |
| 09/25/2026 | INSULATION | Tyler Adams | CANCEL | — |
| 09/18/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND PROCEED | - add board beneath panel to secure service cable to - studor vent will be required at laundry sink - smoke detector not allowed to be installed in garage per nfpa 72 - insulation and vapor barrier required behind exterior wall portion of tub/shower insert - something is leaking in secondary bathroom - insulate all waterlines in crawlspace - hvac has not been roughed |
| 09/15/2026 | MOISTURE BARRIE | Tyler Adams | PASS | — |
| 09/15/2026 | SHEATHING | Tyler Adams | PASS | — |
| 08/06/2026 | WALL SHEATHING | Tyler Adams | CORRECT AND RECALL | - 3X3 FASTENING GRID NOT MET AT GARAGE POST CORNERS, SEE ATTACHED DIAGRAM HIGHLIGHT SECTIONS |
| 08/06/2026 | ROUGH BUILDING | Tyler Adams | CANCEL | — |
| 07/17/2026 | GARAGE SLAB | Tyler Adams | PASS | — |
| 06/25/2026 | FOOTING | Tyler Adams | PASS | — |