104 CAMERON DR

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 5/20/2026
Issued
UNDERSLAB PLUMBING 06/09/2026 PASS
FOUNDATION 06/16/2026 PASS
ROUGH BUILDING 09/11/2026 C&R
SHEATHING 09/11/2026 C&R
MOISTURE BARRIER 09/14/2026 PASS
WALL SHEATHING 09/14/2026 PASS
ROUGH BUILDING 09/22/2026 C&P
INSULATION 09/29/2026 PASS
+1 More
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-110626

MC #

MC2026-356

Issued Date

—

Finaled Date

—

Owner

MEREDITH HOMES INC

Owner Address

76 VAUGHN SCHOOL RD, GRIFFIN, GA 30223

Contractor

MEREDITH HOMES INC

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW CONSTRUCTION

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

3,559

Zoning

A-R

Sprinklers

NO

APN

052 019B

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
09/29/2026 INSULATION Tyler Adams PASS —
09/29/2026 ROUGH BUILDING Tyler Adams PASS —
09/22/2026 ROUGH BUILDING Tyler Adams CORRECT AND PROCEED - MISSING INSULATION AND VAPOR BARRIER ON EXTERIOR WALL PORTION OF TUB - SEAL HOLE BENEATH SECOND FLOOR TUB - NAIL GUARDS NEEDED OVER ELECTRICAL PENETRATIONS OVER GARAGE HEADER - DRAFT BLOCK OVER PANEL - STUD SHOE NEEDED OVER RIGHT DRAIN ARM IN MASTER BATHROOM - STUD NEEDS TO BE REPAIRED WHERE UNUSED OVERBORED HOLE IS BETWEEN MASTER VANITIES - STUD SHOE NEEDED OVER RIGHT DRAIN ARM IN SECONDARY SECOND FLOOR BATHROOM A SMOKE DETECTOR TOO CLOSE TO FAN BOX IN FRONT RIGHT SECOND FLOOR BEDROOM. MUST BE 36 INCHES AWAY FROM EDGE OF FAN BLADES OF FUTURE FAN - NO TEST IN WATERLINES - STUD SHOES NEEDED OVER DRAIN ARM TO WASHING MACHINE STAND PIPE -
09/14/2026 MOISTURE BARRIER Tyler Adams PASS —
09/14/2026 WALL SHEATHING Tyler Adams PASS —
09/11/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL - ELECTRICAL NOT ROUGHED - SHEATHING HAS NOT BEEN PASSED - 3X3 FASTENING GRID DOES NOT SEEM TO HAVE BEEN MET AT GARAGE POST CORNERS
09/11/2026 SHEATHING Tyler Adams CORRECT AND RECALL - MOISTURE BARRIER INSTALLED PRIOR TO PASSING SHEATHING - 3X3 FASTENING GRID DOES NOT SEEM TO HAVE BEEN MET AT GARAGE POST CORNERs
06/16/2026 FOUNDATION Tyler Adams PASS —
06/09/2026 UNDERSLAB PLUMBING Tyler Adams PASS —