102 CAMERON DR

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 5/20/2026
Issued
UNDERSLAB PLUMBING 06/09/2026 PASS
FOUNDATION 06/16/2026 PASS
ROUGH BUILDING 09/11/2026 C&R
SHEATHING 09/11/2026 C&R
MOISTURE BARRIER 09/11/2026 C&R
SHEATHING 09/14/2026 PASS
MOISTURE BARRIER 09/14/2026 PASS
ROUGH BUILDING 09/22/2026 C&P
+2 More
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-100626

MC #

MC2026-355

Issued Date

—

Finaled Date

—

Owner

MEREDITH HOMES INC

Owner Address

76 VAUGHN SCHOOL RD, GRIFFIN, GA 30223

Contractor

MEREDITH HOMES INC

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW CONSTRUCTION

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

2,752

Zoning

A-R

Sprinklers

NO

APN

052 019A

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
09/29/2026 INSULATION Tyler Adams PASS —
09/29/2026 ROUGH BUILDING Tyler Adams PASS —
09/22/2026 ROUGH BUILDING Tyler Adams CORRECT AND PROCEED - NO WATER ON TUB AND DRAINS TO SECOND FLOOR - DRAFT BLOCK MECHANICAL CHASE IN LEFT SECOND FLOOR BEDROOM AT TOP OF STAIRS, THE DIAGONAL PORTION
09/14/2026 SHEATHING Tyler Adams PASS —
09/14/2026 MOISTURE BARRIER Tyler Adams PASS —
09/11/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL - has not passed sheathing or moisture barrier, 90% of siding is installed - draft blocking over panel - no pressure test on waterlines - stud shoes are missing nails - missing nail guards over cables through framing members through out - line sets and condensate are out of wall - back porch ceiling covered prior to rough - frame mechanical chases, and draft block said chases - bath fan in master water closet does not have a grommet on cable entrance - secure and protect cables and wires in attic space a space over garage needs an accessible entrance - space over master bedroom needs an accessible entrance - seal holes beneath tub on second floor - no water on drains and tubs - bath fan and second floor bathroom does not have grommet at cable entrance - double stud shoe need over left drain arm in second floor bathroom - bath fan and master bathroom does not have grommet at cable entrance
09/11/2026 SHEATHING Tyler Adams CORRECT AND RECALL - MOISTURE BARRIER AND SIDING INSTALLED PRIOR TO PASSING SHEATHING
09/11/2026 MOISTURE BARRIER Tyler Adams CORRECT AND RECALL SIDING INSTALLED PRIOR TO PASSING SHEATHING AND MOISTURE BARRIER
06/16/2026 FOUNDATION Tyler Adams PASS —
06/09/2026 UNDERSLAB PLUMBING Tyler Adams PASS —