234 COPPER CROSSING

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 6/1/2026
Issued 06/03/2026
UNDERSLAB PLUMBING 07/14/2026 PASS
FOOTING 07/16/2026 PASS
WALL SHEATHING 08/17/2026 PASS
MOISTURE BARRIER 08/20/2026 C&R
MO 08/24/2026 C&P
COMBINATION ROUGH 09/23/2026 C&R
ROUGH BUILDING 09/29/2026 C&P
COMBINATION ROUGH 10/05/2026 PASS
+1 More
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-310626

MC #

MC2026-341

Issued Date

06/03/2026

Finaled Date

—

Owner

GEORGE EMAMI

Owner Address

1000 HALONA LOOP, FORSYTH, GA 31029

Contractor

PRIMEPOINT VENTURES

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW CONSTRUCTION

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

3,734

Zoning

RLMD

Sprinklers

NO

APN

054C057

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
10/19/2026 PERMANENT POWER Tyler Adams PASS —
10/05/2026 COMBINATION ROUGH Tyler Adams PASS —
09/29/2026 ROUGH BUILDING Tyler Adams CORRECT AND PROCEED - bond to ufer from exterior through brick - bond as gas line is concealed in wall needs to be accessible - stub up conduit at island
09/23/2026 COMBINATION ROUGH Tyler Adams CORRECT AND RECALL - draft blocking over panel - remove green bond screw from panel - stud shoe needed over drain arm to vanity in powder room - missing hangers on two TGI joist over head in laundry room beneath stair landing - no pressure on waterlines - nail guards needed over waterline to ice maker box on laundry room - bond to ufer - smoke detector in master bedroom ceiling appears to be too close to edge of future ceiling fan blades - improper connection of sealtite to floor outlet boxes - pancake box box on back porch is over box fill with two cable penetrations - draft block concealed space to right of shower in second floor bathroom - secure cables to framing members in atticq
08/24/2026 MO Tyler Adams CORRECT AND PROCEED - TAPE PENETRATIONS TO HOUSE WRAP
08/20/2026 MOISTURE BARRIER Kyle Golberg CORRECT AND RECALL NOT ALL WINDOWS AND DOORS INSTALLEd
08/17/2026 WALL SHEATHING Tyler Adams PASS —
07/16/2026 FOOTING Tyler Adams PASS —
07/14/2026 UNDERSLAB PLUMBING Tyler Adams PASS —

Schedule Inspection

Quick Reference

Edmunds #

P-310626

MC #

MC2026-341

Quick Add Inspection
Generate CO
Generate CC