Permit Timeline
In Review
6/1/2026
Issued
06/03/2026
UNDERSLAB PLUMBING
07/13/2026
C&R
T-POLE
07/13/2026
PASS
UNDERSLAB PLUMB
07/17/2026
C&P
ROUGH BUILDING
08/12/2026
C&P
INSULATION
08/19/2026
C&R
COMBINATION ROUGH
08/24/2026
PASS
INSULATION
08/24/2026
PASS
PERMANENT SERVICE
08/28/2026
PASS
+1 More
Permit Finaled
10/16/2026
Certificate Issued
10/23/2026
Project Information
Edmunds #
P-330626
MC #
MC2026-339
Issued Date
06/03/2026
Finaled Date
10/16/2026
Owner
ROSS SMITH
Owner Address
2373 NAPIER AVE, APT A, MACON, GA 31204
Contractor
AMERICAS HOME PLACE
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW CONSTRUCTION
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
1,956
Zoning
A-R
Sprinklers
NO
APN
090 019B
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 10/16/2026 | FINAL | Tyler Adams | PASS | — |
| 08/28/2026 | PERMANENT SERVICE | Tyler Adams | PASS | — |
| 08/24/2026 | COMBINATION ROUGH | Tyler Adams | PASS | — |
| 08/24/2026 | INSULATION | Tyler Adams | PASS | — |
| 08/19/2026 | INSULATION | Kyle Golberg | CORRECT AND RECALL | ROUGH CORRECTIONS NOT made |
| 08/12/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND PROCEED | - MISSING TWO ANCHORS IN FRONT RIGHT BEDROOM - THREE ANCHORS MISSING NUTS AND WASHERS IN FRONT RIGHT BEDROOM - MISSING ANCHOR AT JOINT IN SILL PLATE BENEATH WINDOW IN FRONT MIDDLE BEDROOM - NUT LOOSE ON SILL PLATE ANCHOR BENEATH WINDOW IN FRONT MIDDLE BEDROOM - FILL ALL HOLES IN STUD SHOES OVER DRAINS ARMS - ADD HANGERS AT ATTIC PULL DOWN AND SCUTTLE HOLE FRAMING - PLUMBING VENT FLASHINGS NOT INSTALLED ON ROOF |
| 07/17/2026 | UNDERSLAB PLUMB | Tyler Adams | CORRECT AND PROCEED | - STUB UP UFER GROUND - PROVIDE RECEIPT SHOWING FIBER MESH IN COCRETE MIx |
| 07/13/2026 | UNDERSLAB PLUMBING | Tyler Adams | CORRECT AND RECALL | SLEEVE OVER DRAIN NEEDS TO BE A 6INCH PIPE, TWO NOMINAL PIPES SIZES LARGER THAN PIPE BEING SLEEVED |
| 07/13/2026 | T-POLE | Tyler Adams | PASS | — |