282 WILLIS WILDER DR

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 11/19/2025
Issued 10/08/2026
T-POLE 06/22/2026 PASS
ELECTRICAL 07/01/2026 PASS
MOISTURE BARRIER 07/13/2026 PASS
ROUGH BUILDING 07/30/2026 C&R
ROUGH BUILDING 08/18/2026 C&R
PLUMBING 08/18/2026 C&R
FINAL 08/26/2026 C&R
COMBINATION ROUGH 09/16/2026 PASS
+2 More
Permit Finaled
Certificate Issued

Project Information

Edmunds #

—

MC #

MC2026-277

Issued Date

10/08/2026

Finaled Date

—

Owner

I-READY HOMES & DEVELOPMENT LLC

Owner Address

6132 RIVEROAK TERR, ATLANTA, GA 30349

Contractor

METRO PAL CONTRACTORS. LLC

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

—

Occupancy Group

—

Occupant Load

—

Square Footage

2200

Zoning

—

Sprinklers

—

APN

F10 015

Limitations

—

Inspection History

Date Type Inspector Result Notes
10/8/2026 FINAL TYLER ADAMS CORRECT AND RECALL - condenser unit 2 has a nameplate mac breaker size of 15 amps, a 20 amp is installed - pop off for water heater needs to terminate between 18” and 1.5” above finished grade - smoke detector not allowed in garage per NFPA 72 - door from garage needs to be rated - need to see passing blower door certificate - seal corners of master shower - caulk toilets in place - island outlet not installed, required per ga state electrical amendment as of jan1 2026 - lights not installed on kitchen wall and back porch - outlet not installed over fireplace in living room
09/22/2026 INSULATION Tyler Adams PASS —
09/16/2026 COMBINATION ROUGH Tyler Adams PASS —
08/26/2026 FINAL Tyler Adams CORRECT AND RECALL - MISSING ANCHORS ALL AROUND SUN ROOM - FIR OUT WALL AT ELECTRICAL PANEL TO MAINTAIN R-VALUE - UFER CONNECTION NEEDS TO BE ACCESSIBLE - MISSING HANGERS AT ATTIC PULL DOWN - ANCHORS MISSING NUTS AND WASHERS BY GARAGE POSTS - NO ANCHORS IN BACK WALL OF MASTER BEDROOM - ANCHORS IN MASTER BATHROOM MISSING NUTS AND WASHERS - MISSING ANCHORS BEHIND FIREPLACE BOX - ANCHORS MISSING NUTS AND WASHERS IN LIVING ROOM - RE-INSPECTION FEE WILL BE APPLIED
08/18/2026 ROUGH BUILDING Kyle Golberg CORRECT AND RECALL PREVIOUS CORRECTIONS NOT MADe
08/18/2026 PLUMBING Kyle Golberg CORRECT AND RECALL —
07/30/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL - ANCHORS REQUIRED WITH IN 12 INCHES OF ALL BREAKS AND JOINTS IN EXTERIOR SILL PLATE - FIR OUT WALL AT ELECTRICAL PANEL TO MAINTAIN R-VALUE - UFER CONNECTION NEEDS TO BE ACCESSIBLE - MISSING HANGERS AT ATTIC PULL DOWN - MISSING NAIL GUARD OVER POP OFF DRAIN THROUGH STUD TO EXTERIOR - NO PRESSURE ON WATERLINES - VENT BATHROOM EXHAUST FANS TO EXTERIOR - HVAC HAS NOT BEEN ROUGHED - MISSING ANCHORS ALL THE WAY AROUND BACK PORCH SUN ROOM
07/13/2026 MOISTURE BARRIER Tyler Adams PASS —
07/01/2026 ELECTRICAL Tyler Adams PASS —
06/22/2026 T-POLE Tyler Adams PASS —