220 FLINT ST

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 10/30/2025
Issued
COMBO ROUGH (BMEP) 06/17/2026 C&R
ROUGH BUILDING 07/01/2026 C&R
ROUGH BUILDING 07/21/2026 PASS
INSULATION 07/21/2026 PASS
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-151125

MC #

MC2026-269

Issued Date

—

Finaled Date

—

Owner

ARTHUR FARR

Owner Address

220 FLINT ST, FORSYTH, GA 31029

Contractor

ARTHUR FARR

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

—

Occupancy Group

—

Occupant Load

—

Square Footage

1200

Zoning

—

Sprinklers

—

APN

031 006

Limitations

—

Inspection History

Date Type Inspector Result Notes
07/21/2026 ROUGH BUILDING Tyler Adams PASS —
07/21/2026 INSULATION Tyler Adams PASS —
07/01/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL 1. NAIL GUARDS NEEDED OVER PLUMBING THROUGH FRAMING MEMBERS, WHERE WITH IN 1.5 INCHS OF OUTSIDE EDGE OF FRAMING MEMBERS 2. PLUMBING VENT NEEDS TO EXTEND TO EXTERIOR 3. BATHROOM EXHAUST FAN NEEDS TO BE VENTED TO EXTERIOR
06/17/2026 COMBO ROUGH (BMEP) Tyler Adams CORRECT AND RECALL - BOND ALL METAL BOXES - SECURE ALL CABLES TO FRAMING MEMBERS - GROUND SCREW ON LEFT SWITCH FOR BATHROOM IS NOT TIGHTENED - JUNCTION BOX COVER MISSING FOR CAN LIGHT IN BATHROOM - PLUMBING NOT ROUGHED - SEAL UNUSED HOLE IN DISCONNECT BETWEEN WALLS - DRAFT BLOCKING NEEDED BETWEEN WALLS AND ATTIC - DO NOT SEE A SMOKE DETECTOR ROUGHED - DO NOT SEE ATTIC ACCESS - ARC FAULT AND GROUND FAULT REQUIREMENTS WILL NEED TO BE MET AT FINAL

Schedule Inspection

Quick Reference

Edmunds #

P-151125

MC #

MC2026-269

Quick Add Inspection
Generate CO
Generate CC