Permit Timeline
In Review
10/23/2025
Issued
INSULATION
06/04/2026
PASS
PERMANENT SERVICE
07/13/2026
PASS
FINAL
10/06/2026
C&R
FINAL
10/14/2026
PASS
Permit Finaled
10/14/2026
Certificate Issued
10/23/2026
Project Information
Edmunds #
P-571025
MC #
MC2026-266
Issued Date
—
Finaled Date
10/14/2026
Owner
BISHOP HERRINGTON JR
Owner Address
1399 OLD ZEBULON RD, FORSYTH, GA 31029
Contractor
BISHOP HERRINGTON JR
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
4200
Zoning
A-R
Sprinklers
NO
APN
032 004D
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 10/14/2026 | FINAL | Tyler Adams | PASS | — |
| 10/06/2026 | FINAL | Tyler Adams | CORRECT AND RECALL | - SEAL AROUND LIGHTS AND PENETRATIONS TO SIDING - LEFT LIGHT BY GARAGE NOT FLUSH TO SIDING - MISSING VACUUM BREAKERS ON HOSE BIB BY METER - ALL EXTERIOR OUTLETS NEED TO BE WR MARKED FOR WET/DAMP LOCATIONS - NEED TO SEE PASSING BLOWER DOOR CERTIFICATE - LAND ROMEX AT TOP OF ATTIC PULL DOWN IN GARAGE INTO A BOX - WATER HAMMER ARRESTOR A NEEDED AT WASHING MACHINE SUPPLY BOX - ONLY THE FIRST OUTLET IN A SERIES NEEDS TO BE A GFCI OUTLET. THE REST OF THE OUTLETS IN THAT SERIES WILL BE PROTECTED DOWNSTREAM. - CAULK TOILETS IN PLACE - WATER HAMMER ARRESTOR NEEDED AT DISHWASHER SUPPLY VALVE |
| 07/13/2026 | PERMANENT SERVICE | Tyler Adams | PASS | — |
| 06/04/2026 | INSULATION | Tyler Adams | PASS | — |