Permit Timeline
In Review
10/6/2025
Issued
10/6/2025
ELECTRICAL
07/01/2026
PASS
MOISTURE BARRIER
07/13/2026
PASS
COMBINATION ROUGH
09/16/2026
PASS
FINAL
10/08/2026
C&R
FINAL
10/13/2026
PASS
Permit Finaled
10/13/2026
Certificate Issued
10/23/2026
Project Information
Edmunds #
P-221025
MC #
MC2026-258
Issued Date
10/6/2025
Finaled Date
10/13/2026
Owner
JAMES & SHERRY WALLACE
Owner Address
1190 JOSEY ROAD, FORSYTH, GA 31029
Contractor
RDG VENTURES LLC
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
5,878
Zoning
A-R
Sprinklers
NO
APN
055 012
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 10/13/2026 | FINAL | Tyler Adams | PASS | — |
| 10/08/2026 | FINAL | Tyler Adams | CORRECT AND RECALL | - condenser unit 2 has a nameplate mac breaker size of 15 amps, a 20 amp is installed - pop off for water heater needs to terminate between 18” and 1.5” above finished grade - smoke detector not allowed in garage per NFPA 72 - door from garage needs to be rated - need to see passing blower door certificate - seal corners of master shower - caulk toilets in place - island outlet not installed, required per ga state electrical amendment as of jan1 2026 - lights not installed on kitchen wall and back porch - outlet not installed over fireplace in living room |
| 09/16/2026 | COMBINATION ROUGH | Tyler Adams | PASS | — |
| 07/13/2026 | MOISTURE BARRIER | Tyler Adams | PASS | — |
| 07/01/2026 | ELECTRICAL | Tyler Adams | PASS | — |