300 CREEKSIDE TRAIL

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 10/3/2025
Issued
ROUGH BUILDING 08/26/2026 C&R
ROUGH BUILDING 10/16/2026 PASS
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-211025

MC #

MC2026-257

Issued Date

—

Finaled Date

—

Owner

MARK & SKYLAR LUMSDEN

Owner Address

300 CREEKSIDE TRAIL, FORSYTH, GA 31029

Contractor

BG DEVELOPMENT & INVESTMENT LLC

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

—

Occupancy Group

—

Occupant Load

—

Square Footage

3460

Zoning

—

Sprinklers

—

APN

056A027A

Limitations

—

Inspection History

Date Type Inspector Result Notes
10/16/2026 ROUGH BUILDING Tyler Adams PASS —
08/26/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL - missing sill plate anchors through out garage and breezeway - missing hangers under landing to stairs in garage - no support beneath landing front right side of landing in garage - windows in breezeway by stairs need to be tempered glass - boca plates required over plumbing penetrations to top and bottom plates - plumbing vents in laundry area have not been extended to exterior - bathe fans need to be vented to exterior - insulate waterlines in exterior walls - bath fan required in master bathroom where freestanding tub will be - - hangers needed where return register was cut into ceiling outside master bedroom - bond all metal electrical boxes - make up service cable in electrical panels - no water on tubs and drains - engineered beams need to be hung with hangers not ledger strips, or have engineers approval - smoke detectors need to be with in twelve inches of the ceiling when wall mounted - no mastic in ac registers - hurricane ties missing on rafter connections - top hung web trusses over head at bases of stairs in basement are not fully bearing in the sill plate - sill plate anchors missing in exterior wall of basement - insulate all 3/4 hot waterlines - nm-b cable under the deck needs to be UF cable - waterlines to framing members in crawlspace - waterline and gas lines need to be sleeved through block wall and crawlspace - Bond to gas line - secure, gas line to framing members in crawlspace - CCST gas line cannot be in contact with gusset plates

Schedule Inspection

Quick Reference

Edmunds #

P-211025

MC #

MC2026-257

Quick Add Inspection
Generate CO
Generate CC