1251 ENGLISH RD

FINALED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 8/26/2025
Issued 9/9/2025
COMBINATION ROUGH 05/19/2026 C&R
COMBO ROUGH 06/01/2026 PASS
INSULATION 06/01/2026 PASS
PERMANENT POWER 06/15/2026 PASS
FINAL 08/05/2026 C&R
FINAL 08/12/2026 PASS
Permit Finaled 8/12/2026
Certificate Issued 10/24/2026

Project Information

Edmunds #

P-250925

MC #

MC2026-251

Issued Date

9/9/2025

Finaled Date

8/12/2026

Owner

BOBBY & STACEY LOGUE

Owner Address

1251 ENGLISH RD, FORSYTH, GA 31029

Contractor

BOBBY & STACEY LOGUE

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

4346

Zoning

A-R

Sprinklers

NO

APN

027 028G

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
08/12/2026 FINAL Tyler Adams PASS —
08/05/2026 FINAL Tyler Adams CORRECT AND RECALL - provide splash blocks at gutter downspouts - missing vacuum breakers at hose bibs - label ac disconnects to correspond with breakers in panel - panel breaker in disconnect panel at meter - land service for accessory structure in meter panel - both condensers show max breaker size on name plate at 25 amps both have a 30 amp breaker installed - need to see passing blower door - caulk toilets in place - p-trap at left and right vanity in master bathroom seem to be leaking - master shower unfinished - master tub unfinished - vent hood not installed, connection has to be made with hard pipe not flex - no hand rail to second floor - clear uninstructed path needed to both air handlers in attic, 20 inches wide - open junction box behind air handler in attic needs a blank cover installed - seal open hole in top plate of wall behind air handler I attic
06/15/2026 PERMANENT POWER Tyler Adams PASS —
06/01/2026 COMBO ROUGH Tyler Adams PASS —
06/01/2026 INSULATION Tyler Adams PASS —
05/19/2026 COMBINATION ROUGH Tyler Adams CORRECT AND RECALL - triple stud shoe needed over horizontal vent penetration in garage wall - stud shoe needed over trap arm to washing machine box in garage wall - fir out wall at panel to maintain r value - bath fan not installed in master shower - bath fan required in master bathroom - exhaust duct not connected to bath fan in water closet of master bathroom - stud shoes needed over drain arms to master vanities - fireplace insert not installed - sill plate anchors required with in 12 inches of all breaks and joints in exterior sill plate - cable in conduit underslab to island needs to be type UF - triple stud shoe needed over drain arm for vanity in jack and Jill restroom - frame mechanical chase in bonus room - studur vents in attic need to be readily accessible or be naturally vented to exterior - missing nail guards over drain arms to vanities through out