Permit Timeline
In Review
8/26/2025
Issued
9/9/2025
COMBINATION ROUGH
05/19/2026
C&R
COMBO ROUGH
06/01/2026
PASS
INSULATION
06/01/2026
PASS
PERMANENT POWER
06/15/2026
PASS
FINAL
08/05/2026
C&R
FINAL
08/12/2026
PASS
Permit Finaled
8/12/2026
Certificate Issued
10/24/2026
Project Information
Edmunds #
P-250925
MC #
MC2026-251
Issued Date
9/9/2025
Finaled Date
8/12/2026
Owner
BOBBY & STACEY LOGUE
Owner Address
1251 ENGLISH RD, FORSYTH, GA 31029
Contractor
BOBBY & STACEY LOGUE
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
4346
Zoning
A-R
Sprinklers
NO
APN
027 028G
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 08/12/2026 | FINAL | Tyler Adams | PASS | — |
| 08/05/2026 | FINAL | Tyler Adams | CORRECT AND RECALL | - provide splash blocks at gutter downspouts - missing vacuum breakers at hose bibs - label ac disconnects to correspond with breakers in panel - panel breaker in disconnect panel at meter - land service for accessory structure in meter panel - both condensers show max breaker size on name plate at 25 amps both have a 30 amp breaker installed - need to see passing blower door - caulk toilets in place - p-trap at left and right vanity in master bathroom seem to be leaking - master shower unfinished - master tub unfinished - vent hood not installed, connection has to be made with hard pipe not flex - no hand rail to second floor - clear uninstructed path needed to both air handlers in attic, 20 inches wide - open junction box behind air handler in attic needs a blank cover installed - seal open hole in top plate of wall behind air handler I attic |
| 06/15/2026 | PERMANENT POWER | Tyler Adams | PASS | — |
| 06/01/2026 | COMBO ROUGH | Tyler Adams | PASS | — |
| 06/01/2026 | INSULATION | Tyler Adams | PASS | — |
| 05/19/2026 | COMBINATION ROUGH | Tyler Adams | CORRECT AND RECALL | - triple stud shoe needed over horizontal vent penetration in garage wall - stud shoe needed over trap arm to washing machine box in garage wall - fir out wall at panel to maintain r value - bath fan not installed in master shower - bath fan required in master bathroom - exhaust duct not connected to bath fan in water closet of master bathroom - stud shoes needed over drain arms to master vanities - fireplace insert not installed - sill plate anchors required with in 12 inches of all breaks and joints in exterior sill plate - cable in conduit underslab to island needs to be type UF - triple stud shoe needed over drain arm for vanity in jack and Jill restroom - frame mechanical chase in bonus room - studur vents in attic need to be readily accessible or be naturally vented to exterior - missing nail guards over drain arms to vanities through out |