3592 OLD ATLANTA HWY

FINALED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 8/20/2025
Issued 8/20/2025
SHEATHING 05/15/2026 PASS
COMBINATION ROUGH 05/22/2026 C&R
COMBO ROUGH 06/01/2026 PASS
INSULATION 06/10/2026 PASS
PERMANENT SERVICE 6/12/2026 PASS
PERMANENT SERVICE 06/15/2026 PASS
FINAL 09/15/2026 C&R
FINAL 09/22/2026 PASS
Permit Finaled 9/22/2026
Certificate Issued 10/26/2026

Project Information

Edmunds #

P-790825

MC #

MC2026-248

Issued Date

8/20/2025

Finaled Date

9/22/2026

Owner

MORGAN SHULZ KEMP

Owner Address

117 BLACKBERRY TRL, JULIETTE, GA 31046

Contractor

CANNON ROOFING COMPANY

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

4948

Zoning

A-R

Sprinklers

NO

APN

017 014G

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
6/12/2026 PERMANENT SERVICE TYLER ADAMS PASS —
09/22/2026 FINAL Tyler Adams PASS —
09/15/2026 FINAL Tyler Adams CORRECT AND RECALL - all exterior outlets require GFCI protection - all your outlets need to be marked WR for wet/damp locations - exterior outlets not under a covering need to be installed with a while in use covers - missing vacuuming breakers at hose bibs - label breakers at disconnect panel - emergency disconnect sticker at meter disconnect is faded - outlets in crawlspace, require GFCI protection - crawlspace door has no finish on it - minimum 10 foot of straw required around exterior of home - paint brick lentils to prevent corrosion - adjust grade to prevent pooling at base of foundation - portions of back porch appear to be higher than 30 inches above finished grade and require guard rail - all outlets in garage require GFCI protection - door from garage to interior home needs to be rated cannot have glazing - caulk toilets in place - waterhammer arresters required at washing machine valves - full size breaker blanks required at bottom of panel - panel needs to be clearly and accurately labeled - afci protection requirements need to be met - hammer arrestor required a dishwasher supply - vent hood connection not made in attic
06/15/2026 PERMANENT SERVICE Tyler Adams PASS —
06/10/2026 INSULATION Tyler Adams PASS —
06/01/2026 COMBO ROUGH Tyler Adams PASS —
05/22/2026 COMBINATION ROUGH Tyler Adams CORRECT AND RECALL - secure cables with in 6 inches of single boxes and 8 inches of larger boxes - insulate waterlines in exterior walls and in garage walls - install stud shoes with 10d nails not deck screw or roofing nails - water and drain lines through top and sill plates require boca plates 5”x8” plates - no smoke interconnected smoke detector outside master bedroom - heel inlet 90 used in ceiling of master bathroom needs to be a combination wye fitting - vent tees need to be inverted to with the slope conveying air upward - triple stud shoe needed over drain arm to kitchen sink - no interconnected smoke detector outside outside secondary bedrooms - missing hurricane straps on rafter to wall connections - seal beneath tubs - no bath fan roughed in bonus bathroom - no interconnected smoke in bonus room or outside bonus room - wiring in attic ceiling needs to be secured and protected, cannot be ran across decking needs to be beneath decking or provide protection through other means - hood exhaust incomplete - all smoke detectors need to be interconnected, one required in each bedroom with in 12” of high point, and one required outside each bedroom with in 21’ and with in 12” of high point. One required in bonus room and one outside bonus room. All required smoke detectors need to be interconnected with 12-3 cable - insulate all waterlines in crawlspace -
05/15/2026 SHEATHING Tyler Adams PASS —

Schedule Inspection

Quick Reference

Edmunds #

P-790825

MC #

MC2026-248

Quick Add Inspection