Permit Timeline
In Review
7/14/2025
Issued
08/26/2026
ROUGH BUILDING
8/26/2026
C&R
Permit Finaled
Certificate Issued
Project Information
Edmunds #
—
MC #
MC2026-232
Issued Date
08/26/2026
Finaled Date
—
Owner
CARVER WESTENDORFF
Owner Address
3095 OCTAVIA PLACE, ATLANTA, GA 30340
Contractor
LOVETT SERVICES, INC
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
—
Occupancy Group
—
Occupant Load
—
Square Footage
3443
Zoning
—
Sprinklers
—
APN
036 005F
Limitations
—
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 8/26/2026 | ROUGH BUILDING | TYLER ADAMS | CORRECT AND RECALL | - missing sill plate anchors through out garage and breezeway - missing hangers under landing to stairs in garage - no support beneath landing front right side of landing in garage - windows in breezeway by stairs need to be tempered glass - boca plates required over plumbing penetrations to top and bottom plates - plumbing vents in laundry area have not been extended to exterior - bathe fans need to be vented to exterior - insulate waterlines in exterior walls - bath fan required in master bathroom where freestanding tub will be - - hangers needed where return register was cut into ceiling outside master bedroom - bond all metal electrical boxes - make up service cable in electrical panels - no water on tubs and drains - engineered beams need to be hung with hangers not ledger strips, or have engineers approval - smoke detectors need to be with in twelve inches of the ceiling when wall mounted - no mastic in ac registers - hurricane ties missing on rafter connections - top hung web trusses over head at bases of stairs in basement are not fully bearing in the sill plate - sill plate anchors missing in exterior wall of basement - insulate all 3/4 hot waterlines - nm-b cable under the deck needs to be UF cable - waterlines to framing members in crawlspace - waterline and gas lines need to be sleeved through block wall and crawlspace - Bond to gas line - secure, gas line to framing members in crawlspace - CCST gas line cannot be in contact with gusset plates |