795 OLD INDIAN SPRINGS RD

ISSUED
INTERIOR/EXTERIOR ALTERATIONS

Permit Timeline

In Review 8/6/2025
Issued
FINAL 06/25/2026 PASS
FINAL 08/12/2026 CANCE
CONSULTATION 08/12/2026 C&R
FINAL 09/03/2026 C&R
Permit Finaled
Certificate Issued 10/21/2026

Project Information

Edmunds #

P-460825

MC #

MC2026-214

Issued Date

—

Finaled Date

—

Owner

ALLISON JONES

Owner Address

785 OLD INDIAN SPRINGS RD, FORSYTH, GA 31029

Contractor

PACES RESTORATION

Project Type

INTERIOR/EXTERIOR ALTERATIONS

Description

FIRE DAMAGE REPAIR AND RESTORATION

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

2835

Zoning

A-R

Sprinklers

NO

APN

050 028

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
09/03/2026 FINAL Tyler Adams CORRECT AND RECALL - upstairs right bathroom gfci not working - no hot water in upstairs right bathroom - toilets are not caulked - pull down stairs broken in second floor right bedroom closet, not trimmed either - smoke detectors do not appear to be interconnected, will not sound off when test button is pressed - a/c register not installed in second floor left bedroom closet - second floor left bathroom outlet not gfci protected - tub spout loose in second floor left bathroom - no clear path to air handler in attic - no grommets on line sets to air handler in attic - no fall on condensate drain oat attic air handler - banisters are loose overlooking living room - missing escutcheon at toilet supply line - outlet to left of oven does not appear to be gfci protected - panel needs to be clearly and accurately labeled - nm-b cable not protected beneath sink - s trap beneath kitchen sink needs, 1.5 inch elbow replaced with a sanitary tee fitting and an AAV used to vent sink - island outlet on left does not seem to be gfci protected - hammer arrestor not installed on dish washer supply - free standing tub faucet not installed - hand rail to basement needs to extend all the way to nose of bottom step - double floor joist in ceiling of basement over head at under stair access missing hanger - draft stopping needed at soffit in basement - duct work crushed where entering soffit in back room of basement - if back room of basement is to be a bedroom a second means of egress is requires - septic tank is approved for 3 bedrooms, the house as built has 4 bedrooms - missing vacuum breakers on hose bibs - draft blocking concealer mechanical space to left of stairs in basement - draft block over head space at air handler in basement - seal holes in block to crawlspace from basement - all outlets in basement will be required to be gfci protected - ledger of front porch needs to be installed to rim joist with alternating bolts - blocking needed at bump out for front door beneath porch - no screens on crawl space vents - clean out in yard is busted at combination wye fitting - unfinished untreated wood around front door - hole in vinyl siding to right of meter/disconnect - emergence disconnect sticker at meter/disconnect to faded to read - fully paint all exterior gas line to prevent corrosion - no crawl space door installed - back porch ledger needs to be attached to rim joist with alternating bolts - switch, outlet and light on crawl space not installed - insulation in crawlspace needs to be readdressed, falling and sagging through out - SER cable not properly supported to framing in crawlspace - double lvls in crawlspace are missing hanger to beam in crawlspace. 4 double hangers total - waterlines beneath free standing tub in crawlspace are not properly secured to framing members - grade needs to be sloped away from home 6” with in 10’
08/12/2026 FINAL Tyler Adams CANCEL —
08/12/2026 CONSULTATION Tyler Adams CORRECT AND RECALL - OWNER BROUGH FORWARD MANY CONCERNS SUCH AS BUSTED CLEAN OUT, TRIPPING BREAKERS, BAD WATER PRESSURE AND LACK OF HOT WATER IN MASTER BATHROOM, AS BUILT PLANS WILL BE REQUIRED FROM PACES RESTORATION, LAYOUT DOESN NOT MATCH THE SUBMITTED PLANS. JEREMY HEAD WAS ALSO PRESENT FOR THE CONSULAION WITH MRS. ALLISON JONEs
06/25/2026 FINAL Tyler Adams PASS —