Date Type Inspector Result Notes
10/19/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL - have electrician check nails guards saw multiple missing where cables passed through with in 1.25 inches of outside edge of framing members - insufficient water pressure on waterlines - missing insulation and vapor barrier behind tub/shower insert on wall - missing one double hanger and four single hangers on TGI’s to LVL in main living/kitchen area - conduit not roughed to island - missing double hanger on LVL to LVL connection by back door to porch - missing double stud shoe over left vanity arm in master bathroom - smoke detector in bedroom to right of stairs on second floor appears to be closer than 36 inches from outside edge of ceiling fan blades - B-vent through ceiling and second floor bedroom needs to be shifted over to maintain 1 inch clearance from framing in ceiling - frame, mechanical chase and fire block around B-vent in closet - missing double hangers at attic pulldown - no water on second floor tub and drains - missing double hangers at LVL connection in living area of second floor - dryer vent may exceed 35 foot
09/15/2026 MOISTURE BARRIE Tyler Adams PASS —
09/09/2026 WALL SHEATHING Tyler Adams PASS —
08/14/2026 FOUNDATION Tyler Adams PASS —
08/10/2026 UNDERSLAB PLUMBING Tyler Adams PASS —