291 RUSSELLVILLE RD

FINALED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 5/1/2026
Issued P-200526
UNDERSLAB PLUMBING 05/19/2026 PASS
SLAB 06/05/2026 PASS
WALL SHEATHING 06/30/2026 PASS
FRAMING ROUGH 07/08/2026 C&R
MOISTURE BARRIER 07/08/2026 C&R
ROUGH BUILDING 07/15/2026 PASS
MOISTURE BARRIER 07/15/2026 PASS
INSULATION 07/20/2026 PASS
+3 More
Permit Finaled 9/20/2026
Certificate Issued 10/26/2026

Project Information

Edmunds #

P-200526

MC #

MC2026-149

Issued Date

P-200526

Finaled Date

9/20/2026

Owner

BL&C, LLC

Owner Address

2852 HIGH FALLS ROAD, JACKSON, GA 30233

Contractor

BL&C, LLC

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

2303

Zoning

A-R

Sprinklers

NO

APN

034 A003

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
09/18/2026 FINAL Tyler Adams PASS —
09/15/2026 FINAL Tyler Adams CORRECT AND RECALL - all exterior outlets require GFCI protection - all your outlets need to be marked WR for wet/damp locations - exterior outlets not under a covering need to be installed with a while in use covers - missing vacuuming breakers at hose bibs - label breakers at disconnect panel - emergency disconnect sticker at meter disconnect is faded - outlets in crawlspace, require GFCI protection - crawlspace door has no finish on it - minimum 10 foot of straw required around exterior of home - paint brick lentils to prevent corrosion - adjust grade to prevent pooling at base of foundation - portions of back porch appear to be higher than 30 inches above finished grade and require guard rail - all outlets in garage require GFCI protection - door from garage to interior home needs to be rated cannot have glazing - caulk toilets in place - waterhammer arresters required at washing machine valves - full size breaker blanks required at bottom of panel - panel needs to be clearly and accurately labeled - afci protection requirements need to be met - hammer arrestor required a dishwasher supply - vent hood connection not made in attic
08/12/2026 ELECTRICAL Tyler Adams PASS —
07/20/2026 INSULATION Tyler Adams PASS —
07/15/2026 ROUGH BUILDING Tyler Adams PASS —
07/15/2026 MOISTURE BARRIER Tyler Adams PASS —
07/08/2026 FRAMING ROUGH Tyler Adams CORRECT AND RECALL - windows not installed - insulate waterlines in exterior walls - insulation and vapor barrier needed behind tub/shower insert on exterior wall -
07/08/2026 MOISTURE BARRIER Tyler Adams CORRECT AND RECALL WINDOWS NOT INSTALLED
06/30/2026 WALL SHEATHING Tyler Adams PASS —
06/05/2026 SLAB Tyler Adams PASS —
05/19/2026 UNDERSLAB PLUMBING Tyler Adams PASS —

Schedule Inspection

Quick Reference

Edmunds #

P-200526

MC #

MC2026-149

Quick Add Inspection