Permit Timeline
In Review
4/29/2026
Issued
UNDERSLAB PLUMBING
5/13/2026
PASS
SLAB GRADE
05/19/2026
PASS
FRAMING ROUGH
06/24/2026
PASS
ROUGH BUILDING
08/17/2026
C&R
ROUGH BUILDING
09/18/2026
PASS
INSULATION
10/09/2026
PASS
PERMANENT SERVI
10/20/2026
PASS
Permit Finaled
Certificate Issued
Project Information
Edmunds #
P-130526
MC #
MC2026-147
Issued Date
—
Finaled Date
—
Owner
CURTIS T. MATTHEWS
Owner Address
512 FULTON ST, MCDONOUGH, GA 30253
Contractor
CURTIS T. MATTHEWS
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
—
Occupancy Group
—
Occupant Load
—
Square Footage
8102
Zoning
—
Sprinklers
—
APN
026 A002
Limitations
—
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 5/13/2026 | UNDERSLAB PLUMBING | Tyler Adams | PASS | — |
| 10/20/2026 | PERMANENT SERVI | Tyler Adams | PASS | — |
| 10/09/2026 | INSULATION | Tyler Adams | PASS | — |
| 09/18/2026 | ROUGH BUILDING | Tyler Adams | PASS | — |
| 08/17/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - MISSING 1000 LB STRAPS AT GARAGE PORTALS, EXTEND FROM THE TOP PLATE TO BELOW THE GARAGE HEADERS - GROUNDS HAVE NOT BEEN M MADE UP IN ELECTRICAL BOXES - INSULATE ALL WATERLINES IN EXTERIOR WALLS - ELECTRICAL INCOMPLETE - DRAFT BLOCK CONCEALED SPACE BETWEEN POWDER ROOM AND DINING AREA - DOUBLE HANGER RIGHT SIDE OF KITCHEN MISSING NAILS AND HAS IMPROPER FASTENERS INSTALLED - NAIL GUARDS REQUIRED OVER ELECTRICAL WHEN WITH IN 1.25 INCHES OF OUTSIDE EDGE OF FRAMING MEMBERS, OBSERVED PERIODICALLY THROUGH OUT HOUSE - STUD PACK BENEATH QUADRUPLE LVL BETWEEN KITCHEN AND LIVING ROOM ON LEFT SIDE NEEDS TO HAVE ANOTHER STUD SUPPORTING QUADRUPLE LVL - NAIL GUARDS REQUIRED NEEDED OVER 3/4 PVC CONDUIT THROUGH SILL PLATE LEFT SIDE OF FIREPLACE - DRAFT BLOCKING NEEDED OVER FIREPLACE - BOND ALL METAL ELECTRICAL BOXES - MISSING BATH FAN IN MASTER WATER CLOSET - SMOKE DETECTOR IN MASTER BEDROOM NEEDS TO BE WITH IN 12 INCHES OF THE HIGH POINT OF THE CEILING - SMOKE DETECTOR NOT PERMITTED TO BE IN ATTIC - FRAME MECHANICAL CHASES AND DRAFT BLOCK |
| 06/24/2026 | FRAMING ROUGH | Tyler Adams | PASS | — |
| 05/19/2026 | SLAB GRADE | Tyler Adams | PASS | — |