Permit Timeline
In Review
4/28/2026
Issued
UNDERSLAB PLUMBING
06/05/2026
PASS
SLAB
06/10/2026
PASS
FRAMING ROUGH
08/06/2026
C&P
MOISTURE BARRIER
08/11/2026
PASS
SHEATHING
08/11/2026
PASS
FINAL
09/25/2026
C&R
COMBINATION ROUGH
09/25/2026
C&R
ROUGH BUILDING
09/30/2026
C&R
+2 More
Permit Finaled
Certificate Issued
Project Information
Edmunds #
P-100526
MC #
MC2026-146
Issued Date
—
Finaled Date
—
Owner
JASON OLIVER
Owner Address
1362 HOPEWELL RD, FORSYTH, GA 31029
Contractor
JASON OLIVER
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
—
Occupancy Group
—
Occupant Load
—
Square Footage
4372
Zoning
—
Sprinklers
—
APN
043 002B
Limitations
—
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 10/23/2026 | INSULATION | Tyler Adams | PASS | — |
| 10/23/2026 | ROUGH BUILDING | Tyler Adams | PASS | — |
| 09/30/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | NO CORRECTIONS MADE OTHER THAN PLUMBING CORRECTIONS |
| 09/25/2026 | FINAL | Tyler Adams | CORRECT AND RECALL | - extend thousand pound straps to top plate at garage headers - insulate, waterlines and exterior walls and unconditioned attic space - anchor needed to left of back door in garage within 12 inches - anchor needed to left of break in sill plate beneath landing in garage within 12 inches - sill plate strap at base of stairs beneath outlet not fastened - anchor needed within 12 inches of any break or joint in exterior sill plate - hangers needed beneath landing in garage stairs - secure CSST gas line in wall - insulate all three-quarter inch and larger, hot water lines - smoke detector not allowed to be in garage per NFPA 72 - Boca plate needed over waterline through sill plate to left of tub in secondary bathroom by laundry room - chimney flu incomplete - Boca plate needed over vent pipe sill plate penetration in master water closet - smoke detector outside second floor bedroom needs to be with in 12” of high point in ceiling - no water on drain lines and tub |
| 09/25/2026 | COMBINATION ROUGH | Tyler Adams | CORRECT AND RECALL | - extend thousand pound straps to top plate at garage headers - insulate, waterlines and exterior walls and unconditioned attic space - anchor needed to left of back door in garage within 12 inches - anchor needed to left of break in sill plate beneath landing in garage within 12 inches - sill plate strap at base of stairs beneath outlet not fastened - anchor needed within 12 inches of any break or joint in exterior sill plate - hangers needed beneath landing in garage stairs - secure CSST gas line in wall - insulate all three-quarter inch and larger, hot water lines - smoke detector not allowed to be in garage per NFPA 72 - Boca plate needed over waterline through sill plate to left of tub in secondary bathroom by laundry room - chimney flu incomplete - Boca plate needed over vent pipe sill plate penetration in master water closet - smoke detector outside second floor bedroom needs to be with in 12” of high point in ceiling - no water on drain lines and tub |
| 08/11/2026 | MOISTURE BARRIER | Tyler Adams | PASS | — |
| 08/11/2026 | SHEATHING | Tyler Adams | PASS | — |
| 08/06/2026 | FRAMING ROUGH | Tyler Adams | CORRECT AND PROCEED | - PROVIDED 3X3 FASTENING GRID AT GARAGE POST CORNERS - PROVIDE LOCKING AT HORIZONTAL SHEATHING JOINS NAIL OFF EVERY INCHES |
| 06/10/2026 | SLAB | Tyler Adams | PASS | — |
| 06/05/2026 | UNDERSLAB PLUMBING | Tyler Adams | PASS | — |