1362 HOPEWELL RD

ISSUED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 4/28/2026
Issued
UNDERSLAB PLUMBING 06/05/2026 PASS
SLAB 06/10/2026 PASS
FRAMING ROUGH 08/06/2026 C&P
MOISTURE BARRIER 08/11/2026 PASS
SHEATHING 08/11/2026 PASS
FINAL 09/25/2026 C&R
COMBINATION ROUGH 09/25/2026 C&R
ROUGH BUILDING 09/30/2026 C&R
+2 More
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-100526

MC #

MC2026-146

Issued Date

—

Finaled Date

—

Owner

JASON OLIVER

Owner Address

1362 HOPEWELL RD, FORSYTH, GA 31029

Contractor

JASON OLIVER

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

—

Occupancy Group

—

Occupant Load

—

Square Footage

4372

Zoning

—

Sprinklers

—

APN

043 002B

Limitations

—

Inspection History

Date Type Inspector Result Notes
10/23/2026 INSULATION Tyler Adams PASS —
10/23/2026 ROUGH BUILDING Tyler Adams PASS —
09/30/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL NO CORRECTIONS MADE OTHER THAN PLUMBING CORRECTIONS
09/25/2026 FINAL Tyler Adams CORRECT AND RECALL - extend thousand pound straps to top plate at garage headers - insulate, waterlines and exterior walls and unconditioned attic space - anchor needed to left of back door in garage within 12 inches - anchor needed to left of break in sill plate beneath landing in garage within 12 inches - sill plate strap at base of stairs beneath outlet not fastened - anchor needed within 12 inches of any break or joint in exterior sill plate - hangers needed beneath landing in garage stairs - secure CSST gas line in wall - insulate all three-quarter inch and larger, hot water lines - smoke detector not allowed to be in garage per NFPA 72 - Boca plate needed over waterline through sill plate to left of tub in secondary bathroom by laundry room - chimney flu incomplete - Boca plate needed over vent pipe sill plate penetration in master water closet - smoke detector outside second floor bedroom needs to be with in 12” of high point in ceiling - no water on drain lines and tub
09/25/2026 COMBINATION ROUGH Tyler Adams CORRECT AND RECALL - extend thousand pound straps to top plate at garage headers - insulate, waterlines and exterior walls and unconditioned attic space - anchor needed to left of back door in garage within 12 inches - anchor needed to left of break in sill plate beneath landing in garage within 12 inches - sill plate strap at base of stairs beneath outlet not fastened - anchor needed within 12 inches of any break or joint in exterior sill plate - hangers needed beneath landing in garage stairs - secure CSST gas line in wall - insulate all three-quarter inch and larger, hot water lines - smoke detector not allowed to be in garage per NFPA 72 - Boca plate needed over waterline through sill plate to left of tub in secondary bathroom by laundry room - chimney flu incomplete - Boca plate needed over vent pipe sill plate penetration in master water closet - smoke detector outside second floor bedroom needs to be with in 12” of high point in ceiling - no water on drain lines and tub
08/11/2026 MOISTURE BARRIER Tyler Adams PASS —
08/11/2026 SHEATHING Tyler Adams PASS —
08/06/2026 FRAMING ROUGH Tyler Adams CORRECT AND PROCEED - PROVIDED 3X3 FASTENING GRID AT GARAGE POST CORNERS - PROVIDE LOCKING AT HORIZONTAL SHEATHING JOINS NAIL OFF EVERY INCHES
06/10/2026 SLAB Tyler Adams PASS —
06/05/2026 UNDERSLAB PLUMBING Tyler Adams PASS —

Schedule Inspection

Quick Reference

Edmunds #

P-100526

MC #

MC2026-146

Quick Add Inspection
Generate CO
Generate CC