2405 LASSITER RD

FINALED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 4/3/2026
Issued 10/21/2026
UNDERGROUND/ SLAB PLUMBING 6/1/2026 PASS
SHEATHING 07/08/2026 PASS
MOISTURE BARRIER 07/24/2026 PASS
GAS TEST 07/24/2026 PASS
ROUGH BUILDING 07/30/2026 C&R
ROUGH BUILDING 08/04/2026 PASS
INSULATION 08/10/2026 PASS
PERMANENT SERVI 09/08/2026 PASS
+2 More
Permit Finaled 10/19/2026
Certificate Issued 10/25/2026

Project Information

Edmunds #

P-360426

MC #

MC2026-134

Issued Date

10/21/2026

Finaled Date

10/19/2026

Owner

JONATHAN GARMAN & KELLIE FENNELL

Owner Address

2405 LASSITER RD, FORSYTH, GA 31029

Contractor

JONATHAN GARMAN & KELLIE FENNELL

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

N/A

Square Footage

4501

Zoning

A-R

Sprinklers

NO

APN

073 048

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
6/1/2026 UNDERGROUND/ SLAB PLUMBING TYLER ADAMS PASS —
10/19/2026 FINAL Tyler Adams PASS —
10/14/2026 FINAL Tyler Adams CORRECT AND RECALL - all exterior outlets need to be marked WR for wet/damp locations - label condenser disconnects in relation to their breaker label at panel - strap 1.5 inch conduit out of disconnect to left of condensers - paint exterior black iron gas line and fittings to prevent corrosion - strap 3/4 conduit to right of meter combo - label breaker in service panel at meter combo - label air handlers and condensers in panel so that they are distinguishable from one another example 1 and 2 A and B - bathroom outlets require 20 amps - breakers 12 and 13 require afci protection - loose UF cable under kitchen sink needs to be in a box and protected where exposed - no outlet at kitchen island, required with ga amendment as of Jan 1 2026 - only first outlet in a series requires the gfci outlet, all down stream outlets are protected off of the load side of the gfci outlet - hand rail from landing to top floor needs to be continuous to the top riser, there is no hand rail from where it terminates to the newel post to the rope riser - seal tite conduit needs to be attached to air handlers with approved fittings
09/08/2026 PERMANENT SERVI Tyler Adams PASS —
08/10/2026 INSULATION Tyler Adams PASS —
08/04/2026 ROUGH BUILDING Tyler Adams PASS —
07/30/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL - ONE OUTLET IN GARAGE HAS TO BE 20 AMPS REQUIRED BRANCH CIRCUIT - GET GROUND REQUIRED TO BE # 6 COPPER - SMOKE DETECTOR NOT ALLOWED IN GARAGE PER NFPA 72 - INSULATE ALL 3/4 HOT WATERLINES PER ENERGY CODE - STUD SHOE NEEDED OVER DRAIN ARM TO VANITY IN POWDER ROOM - NM-B NOT PERMITTED TO BE IN RACEWAY BENEATH SLAB, NEEDS TO BE TYPE UF CABLE. CONSIDERED DAMP LOCATION - NO WATER ON DRAINS AND TUBS - SEAL HOLE BENEATH TUB ON SECOND FLOOR
07/24/2026 MOISTURE BARRIER Tyler Adams PASS —
07/24/2026 GAS TEST Tyler Adams PASS —
07/08/2026 SHEATHING Tyler Adams PASS —

Schedule Inspection

Quick Reference

Edmunds #

P-360426

MC #

MC2026-134

Quick Add Inspection