Permit Timeline
In Review
3/17/2026
Issued
07/10/2026
SLAB GRADE
5/13/2026
PASS
WALL SHEATHING
06/23/2026
PASS
ROUGH BUILDING
07/10/2026
C&R
MOISTURE BARRIER
07/10/2026
PASS
ROUGH BUILDING
07/16/2026
PASS
INSULATION
07/22/2026
PASS
PERMANENT SERVICE
08/12/2026
PASS
FINAL
09/21/2026
C&R
+1 More
Permit Finaled
9/25/2026
Certificate Issued
10/25/2026
Project Information
Edmunds #
P-380326
MC #
MC2026-122
Issued Date
07/10/2026
Finaled Date
9/25/2026
Owner
NICHOLAS BENSON
Owner Address
16087 HWY 74, CULLODEN, GA 31016
Contractor
CUSTOM HOMES BY JOEY
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
3601
Zoning
A-R
Sprinklers
NO
APN
100114
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 5/13/2026 | SLAB GRADE | Tyler Adams | PASS | — |
| 09/25/2026 | FINAL | Tyler Adams | PASS | — |
| 09/21/2026 | FINAL | Tyler Adams | CORRECT AND RECALL | - all exterior outlets need to be marked WR for wet/damp locations - caulk toilets and vanity tops in place - condenser disconnect is bypassed, pull handle is missing - provide splash blocks at gutter down spouts - posts need to be set on brackets |
| 08/12/2026 | PERMANENT SERVICE | Tyler Adams | PASS | — |
| 07/22/2026 | INSULATION | Tyler Adams | PASS | — |
| 07/16/2026 | ROUGH BUILDING | Tyler Adams | PASS | — |
| 07/10/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - MISSING HURRICANE TIES AT RAFTER TO TOP PLATE CONNECTIONS - SECURE WATERLINES TO FRAMING MEMBERS - SMOKE DETECTOR IN MASTER BEDROOM NEEDS TO BE LOCATED WITHIN 12 INCHES OF HIGH POINT IN CEILING - STUD SHOES REQUIRED OVER DRAIN ARM TO KITCHEN SINK WHERE STUDS HAVE BEEN OVER BORED - INSULATION AND VAPOR BARRIER REQUIRED BEHIND TUB/SHOWER INSERTS ON EXTERIOR WALLS - SILL PLATE ANCHORS REQUIRED WITH IN 12 INCHES OF ALL BREAKS AND JOINTS OF EXTERIOR SILL PLATE - SECURE CSST GAS LINE TO FRAMING MEMBERS - INSUFFICIENT PRESSURE ON GAS LINE - STUD SHOE REQUIRED OVER DRAIN ARM TO WASHING MACHINE STAND PIPE WHERE STUD HAS BEEN OVER BORED - JOIST HANGERS NEEDED WHERE CEILNG JOIST HAVE BEEN ALTERED FOR RETURN IN CEILNG OUTSIDE OF LAUNDRY ROOM |
| 07/10/2026 | MOISTURE BARRIER | Tyler Adams | PASS | — |
| 06/23/2026 | WALL SHEATHING | Tyler Adams | PASS | — |