Permit Timeline
In Review
3/6/2026
Issued
06/02/2026
COMBINATION ROUGH
5/13/2026
C&R
MOISTURE BARRIER
5/13/2026
C&R
T-POLE
5/14/2026
C&R
COMBINATION ROUGH
05/22/2026
PASS
MOISTURE BARRIER
05/22/2026
PASS
INSULATION
06/02/2026
PASS
PERMANENT SERVICE
06/05/2026
PASS
FINAL
07/31/2026
PASS
Permit Finaled
7/31/2026
Certificate Issued
10/24/2026
Project Information
Edmunds #
P-190326
MC #
MC2026-118
Issued Date
06/02/2026
Finaled Date
7/31/2026
Owner
JEFFREY & LEE ANN DUNCAN
Owner Address
333 JONELL DR, GRAY, GA 31032
Contractor
AMERICA'S HOME PLACE
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
3157
Zoning
A-R
Sprinklers
NO
APN
091 A026
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 5/14/2026 | T-POLE | Tyler Adams | CORRECT AND RECALL | Could not locate a temporary power pole |
| 5/13/2026 | COMBINATION ROUGH | Tyler Adams | CORRECT AND RECALL | - install 2 in.² washers at anchors both sides of garage portal - windows not installed or on site - tape all joints on exterior moisture barrier - waterlines need to be re-secured where electricians have broken it loose from straps - hanger nails missing on hangers at roof truss over wall between master suite and kitchen - stud shoes in master bathroom need to be installed with 10D nails not Sheetrock screws - missing hurricane straps on back porch truss connections - missing hurricane straps on front porch truss connections - gas not roughed to fireplace insert |
| 5/13/2026 | MOISTURE BARRIER | Tyler Adams | CORRECT AND RECALL | WINDOWS MISSING TAPE JOINTS IN MOISTURE BARRIER |
| 07/31/2026 | FINAL | Tyler Adams | PASS | — |
| 06/05/2026 | PERMANENT SERVICE | Tyler Adams | PASS | — |
| 06/02/2026 | INSULATION | Tyler Adams | PASS | — |
| 05/22/2026 | COMBINATION ROUGH | Tyler Adams | PASS | — |
| 05/22/2026 | MOISTURE BARRIER | Tyler Adams | PASS | — |