Permit Timeline
In Review
3/4/2026
Issued
SHEATHING
06/03/2026
C&R
SHEATHING
06/11/2026
PASS
FOOTING
6/30/2026
PASS
T-POLE
6/30/2026
PASS
FOOTING
07/01/2026
PASS
T-POLE
07/01/2026
PASS
WALL SHEATHING
07/16/2026
PASS
ROUGH BUILDING
10/21/2026
C&R
Permit Finaled
Certificate Issued
Project Information
Edmunds #
P-130326
MC #
MC2026-117
Issued Date
—
Finaled Date
—
Owner
CHARLES POLLOCK
Owner Address
768 CRAWFORD RD, MACON, GA 31210
Contractor
UPSHAW CONSTRUCTION
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
—
Occupancy Group
—
Occupant Load
—
Square Footage
8623
Zoning
—
Sprinklers
—
APN
112 048
Limitations
—
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 6/30/2026 | FOOTING | TYLER ADAMS | PASS | — |
| 6/30/2026 | T-POLE | TYLER ADAMS | PASS | — |
| 10/21/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - missing sill plate anchors at joints/breaks in exterior sill plate of garage - missing hurricane ties at rafter to top plate connections - draft block firred out wall around basement stairs - draft block concealed space to left of basement stairs by entrance door at breezeway - plumbing vent is ran across attic pull down access by powder room - missing boca plate over 3/4 waterline through sill plate to leafy of entrance door at breezeway - fireplace insert and flue not installed - smoke detectors need to be roughed with in 12 inches of high point in ceiling - boca plates needed over waterlines through sill plate at knee-wall in master shower - master bathroom exhaust fan not vented to exterior - insulate all 3/4 hot waterlines - main shut off needed on water main where it enters basement - service is not bonded to UFER |
| 07/16/2026 | WALL SHEATHING | Tyler Adams | PASS | — |
| 07/01/2026 | FOOTING | Tyler Adams | PASS | — |
| 07/01/2026 | T-POLE | Tyler Adams | PASS | — |
| 06/11/2026 | SHEATHING | Tyler Adams | PASS | — |
| 06/03/2026 | SHEATHING | Tyler Adams | CORRECT AND RECALL | — |