Permit Timeline
In Review
3/4/2026
Issued
FOOTING
5/13/2026
PASS
WALL SHEATHING
06/24/2026
PASS
MOISTURE BARRIER
07/23/2026
C&P
ROUGH BUILDING
08/13/2026
C&R
ROUGH BUILDING
08/24/2026
C&R
ROUGH BUILDING
08/31/2026
C&R
INSULATION
09/21/2026
PASS
COMBINATION ROUGH
09/21/2026
PASS
Permit Finaled
Certificate Issued
Project Information
Edmunds #
P-140326
MC #
MC2026-115
Issued Date
—
Finaled Date
—
Owner
CHARLES MAYHUE
Owner Address
207 WESTCHESTER DR, MACON, GA 31210
Contractor
RESCORP LLC
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
—
Occupancy Group
—
Occupant Load
—
Square Footage
5917
Zoning
—
Sprinklers
—
APN
108 007
Limitations
—
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 5/13/2026 | FOOTING | Tyler Adams | PASS | — |
| 09/21/2026 | INSULATION | Tyler Adams | PASS | — |
| 09/21/2026 | COMBINATION ROUGH | Tyler Adams | PASS | — |
| 08/31/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - PLUMBING VENT FLASHING NOT INSTALLED ON ROOF PENETRATION - NO WATER ON DRAIN LINES, AIR IS NOT A CODE ACCEPTABLE TEST MEDIUM ON PVC PIPE - SEAL HOLES BENEATH TUBS FOR PLUMBING PENETRATION - SEAL PLUMBING PENETRATION TO FLOOR ON FIREPLACE BOX - ELECTRICAL SWITCH BOXES STILL HANGING LOOSE FROM WALL TO LEFT OF FRONT ENTRANCE - REINSPECTION FEE APPLIED |
| 08/24/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - INSULATE ALL WATERLINES IN CRAWLSPACE - NO WATER ON TUBS AND DRAIN LINES - PLUMBING VENT PENETRATIONS HAVE NOT BEEN MADE IN ROOF - AIR NOT ALLOWED AS TEST MEDIUM FOR PLASTIC PIPe |
| 08/13/2026 | ROUGH BUILDING | Tyler Adams | CORRECT AND RECALL | - ANCHORS MISSING WITH IN 12” OF JOINTS, BREAKS AND DOOR OPENINGS OF EXTERIOR WALLS OF GARAGES - PLUMBING PENETRATIONS TO TOP AND SILL PLATES REQUIRE PROTECTION THAT EXTENDS 2 INCHES ABOVE/BELOW PLATE. WATER LINES AND DWV - HURRICANE TIES MISSING AT RAFTER TO TOP PLATE CONNECTIONS - PLUMBING DRAIN WASTE AND VENT INCOMPLETE - WATERLINES GROMMETS LOOSE FROM BRACKETS - INSULATE ALL 3/4 AND LARGER HOT WATERLINES - INSULATE ALL WATERLINES IN EXTERIOR WALLS - NO PRESSURE ON WATERLINES - ELECTRICAL BOXES HANGING LOOSES FROM WALL AROUND FRONT ENTRANCE DOOR - NO MASTIC INSIDE OF A/C REGISTERS - REMOVE BOND SCREW FROM PANELS - FRAME CHASE FOR LINE SETS IN MASTER CLOSET - SECURE CABLES ACROSS FRAMING MEMBERS IN ATTIC - SECURE SERVICE CABLE TO FRAMING IN CRAWLSPACE EVERY 4.5 FOOT WITH STAPLES OR CABLE STRAPS - PROPERLY SECURE MAIN BUILDING DRAIN IN CRAWLSPACE TO MAINTAIN MINIMUM 1/8 PER FOOT ON 4 INCH AND 1/4 PER FOOT ON 3 INCH’S AND SMALLER - INSULATE ALL WATERLINES IN NATURALLY VENTED CRAWLSPACE - 1/2” BLUE WATERLINE OVERHEAD AT CRAWLSPACE ENTRANCE IS LINKED WHERE RADIUS TURN IS TOO TIGHT AGAINS FLOOR JOIST |
| 07/23/2026 | MOISTURE BARRIER | Tyler Adams | CORRECT AND PROCEED | TAPE ALL JOINTS AND SEAMS |
| 06/24/2026 | WALL SHEATHING | Tyler Adams | PASS | — |