Permit Timeline
In Review
2/10/2026
Issued
2/10/2026
SHEATHING
05/22/2026
C&P
COMBINATION ROUGH
6/10/2026
C&P
MOISTURE BARRIER
6/10/2026
PASS
GAS TEST
6/10/2026
PASS
COMBO ROUGH (BMEP)
06/10/2026
C&P
INSULATION
06/16/2026
C&R
TEMP TO PERM
07/21/2026
PASS
FINAL
08/21/2026
C&R
+1 More
Permit Finaled
8/26/2026
Certificate Issued
10/15/2026
Project Information
Edmunds #
P-350226
MC #
MC2026-107
Issued Date
2/10/2026
Finaled Date
8/26/2026
Owner
RICHARD & SHANA ODETTE
Owner Address
222 STACY LANE, WARNER ROBINS, GA 31088
Contractor
TRINITY CUSTOM HOMES
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
3652
Zoning
A-R
Sprinklers
NO
APN
110 017B
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 6/10/2026 | COMBINATION ROUGH | TYLER ADAMS | CORRECT AND PROCEED | - REPLACE NM-B CABLE UNDERSLAB WITH TYPE UF - INSULATE ALL 3/4” HOT WATERLINES - |
| 6/10/2026 | MOISTURE BARRIER | TYLER ADAMS | PASS | — |
| 6/10/2026 | GAS TEST | TYLER ADAMS | PASS | — |
| 08/26/2026 | FINAL | Tyler Adams | PASS | — |
| 08/21/2026 | FINAL | Kyle Golberg | CORRECT AND RECALL | 1. VENT HOOD NOT INSTALLED 2. GAS NOT INSTALLED. 3. BATHROOM VANITIES NOT INSTALLED 4. CAULK AROUND TOILETS 5. WATER AROUND HALF BATH FAUCET NEAR MASTER COULD BE LEAKING 6. LABEL EMERGENCY DISCONNECT 7. FIX UNCLEAR ELECTRICAL PANEL LABELs |
| 07/21/2026 | TEMP TO PERM | Tyler Adams | PASS | — |
| 06/16/2026 | INSULATION | Tyler Adams | CORRECT AND RECALL | COULD NOT MAKE IT UP DRIVEWAY IN MUD |
| 06/10/2026 | COMBO ROUGH (BMEP) | Tyler Adams | CORRECT AND PROCEED | — |
| 05/22/2026 | SHEATHING | Tyler Adams | CORRECT AND PROCEED | - 3X3 FASTENING GRID NOT MET AT GARAGE HEADER CROSS SECTION - NAIL OFF TO BOTH STUDS BOTH SIDES OF GARAGE |