151 DERBY DR

FINALED
NEW SINGLE FAMILY RESIDENTIAL

Permit Timeline

In Review 1/29/2026
Issued 1/29/2026
MOISTURE BARRIER 06/02/2026 C&P
ROUGH BUILDING 07/08/2026 C&R
ROUGH BUILDING 07/14/2026 PASS
MOISTURE BARRIER 07/14/2026 PASS
INSULATION 07/20/2026 C&P
PERMANENT SERVICE 08/17/2026 C&R
PERMANENT SERVI 08/25/2026 PASS
FINAL 10/07/2026 PASS
Permit Finaled 10/7/2026
Certificate Issued 10/25/2026

Project Information

Edmunds #

P-130226

MC #

MC2026-102

Issued Date

1/29/2026

Finaled Date

10/7/2026

Owner

PRIMEPOINT VENTURES

Owner Address

45 N. KIMBALL ST STE A, FORSYTH, GA 31029

Contractor

PRIMEPOINT VENTURES

Project Type

NEW SINGLE FAMILY RESIDENTIAL

Description

NEW SFR

Technical Details

Construction Type

V-B

Occupancy Group

R-3

Occupant Load

—

Square Footage

4820

Zoning

A-R

Sprinklers

NO

APN

015A 026

Limitations

NONE

Inspection History

Date Type Inspector Result Notes
10/07/2026 FINAL Tyler Adams PASS —
08/25/2026 PERMANENT SERVI Tyler Adams PASS —
08/17/2026 PERMANENT SERVICE Tyler Adams CORRECT AND RECALL - PANEL COVER NOT INSTALLED - DISCONNECT IS MISSING FROM METER/DISCONNECT CAn
07/20/2026 INSULATION Tyler Adams CORRECT AND PROCEED INSULATE BEHIND PANEL
07/14/2026 ROUGH BUILDING Tyler Adams PASS —
07/14/2026 MOISTURE BARRIER Tyler Adams PASS —
07/08/2026 ROUGH BUILDING Tyler Adams CORRECT AND RECALL - duct for vent hood broken at 90 - floor outlets need to have pvc conduit glued in, transitioning to sealtite not allowed, need to elbow up into wall in living room and kitchen - insulation and vapor barrier missing behind tub/shower inserts - stud shoes need to be installed with 10d nails not roofing nails - missing hangers in ceiling of left bedroom off of jack and Jill restroom
06/02/2026 MOISTURE BARRIER Tyler Adams CORRECT AND PROCEED 1. Window not installed in garage 2. Floor outlet boxes in living room are roughed with carflex, needs to be pvc and be glued into the outlet boxes. Correction needs to be verified before concrete is poured over trench