Permit Timeline
In Review
1/13/2026
Issued
1/13/2026
PERMANENT POWER
06/10/2026
PASS
FINAL
08/12/2026
C&R
FINAL
08/28/2026
PASS
Permit Finaled
8/28/2026
Certificate Issued
10/26/2026
Project Information
Edmunds #
P-440126
MC #
MC2026-096
Issued Date
1/13/2026
Finaled Date
8/28/2026
Owner
ABIGAIL IVEY & JUSTIN THOMAS
Owner Address
2742 HWY 42 S, FORSYTH, GA 31029
Contractor
HUNT DEVELOPMENT INC
Project Type
NEW SINGLE FAMILY RESIDENTIAL
Description
NEW SFR
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
3376
Zoning
A-R
Sprinklers
NO
APN
043 013A
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 08/28/2026 | FINAL | Tyler Adams | PASS | — |
| 08/12/2026 | FINAL | Tyler Adams | CORRECT AND RECALL | - ALL EXTERIOR OUTLETS NEED TO BE WR MARKED FOR WET/DAMP LOCATIONS - MISSING UNIVERSAL BOND BAR AT METER - PIPE CONDENSATE DRAIN AWAY FROM FOUNDATION - 35 AMP - CAN TRIM HANGING LOOSE IN MASTER BEDROOM - TRAP UNDER KITCHEN SINK NEEDS TO HAVE A TEE FITTING IN PLACE OF THE 90 ELBOW WITH A STUDOR VENT OUT THE TOP, CURRENT CONFIGURATION IS A S TRAP - NEED TO HAVE A MINI HAMMER ARRESTOR AT DISH WASHER SUPPLY LINE - DISH WASHER DISCHARGE LINE NEEDS TO BE STRAPPED UP HIGH TO HAVE A HIGH LOOP - LIVING ROOM CIRCUIT NEEDS TO BE AFCI PROTECTED - NEED TO SEE PASSING BLOWER DOOR CERTIFICATE |
| 06/10/2026 | PERMANENT POWER | Tyler Adams | PASS | — |