40 RIVER RAPIDS DR

ISSUED
INTERIOR/EXTERIOR ALTERATIONS

Permit Timeline

In Review 1/13/2026
Issued
COMBINATION ROUGH 05/15/2026 C&R
COMBINATION ROUGH 05/20/2026 PASS
INSULATION 05/29/2026 PASS
TEMP TO PERM POWER 08/27/2026 PASS
FINAL 10/02/2026 C&R
Permit Finaled
Certificate Issued

Project Information

Edmunds #

P-430126

MC #

MC2026-073

Issued Date

—

Finaled Date

—

Owner

ELIZABETH & MATTHEW MARLOWE

Owner Address

40 RIVER RAPIDS DR, FORSYTH, GA 31029

Contractor

PACES RESTORATION

Project Type

INTERIOR/EXTERIOR ALTERATIONS

Description

RENOVATION DUE TO FIRE DAMAGE

Technical Details

Construction Type

—

Occupancy Group

—

Occupant Load

—

Square Footage

3200

Zoning

—

Sprinklers

—

APN

038A014

Limitations

—

Inspection History

Date Type Inspector Result Notes
10/02/2026 FINAL Tyler Adams CORRECT AND RECALL - expansion tank at water heater needs to be strapped to wall, cannot be supported by pipe - top two breakers on not labeled in right panel - left condenser has name plate max breaker size of 25 amps a 30 amp is installed - remove smoke detector from garage not allowed per nfpa 72 - paint exterior gas line - handrail needs to be continuous from first floor to second floor
08/27/2026 TEMP TO PERM POWER Tyler Adams PASS —
05/29/2026 INSULATION Tyler Adams PASS —
05/20/2026 COMBINATION ROUGH Tyler Adams PASS —
05/15/2026 COMBINATION ROUGH Tyler Adams CORRECT AND RECALL - missing hangers in kitchen ceiling over concrete cut - to test on second floor drains and tub - seal beneath second floor tub - missing plumbing vent flashing on rough - draft block mechanical chase second floor bedroom by bonus room