Permit Timeline
In Review
3/3/2026
Issued
FINAL
06/25/2026
C&R
FINAL
06/30/2026
PASS
Permit Finaled
6/30/2026
Certificate Issued
10/25/2026
Project Information
Edmunds #
P-120326
MC #
MC2026-017
Issued Date
—
Finaled Date
6/30/2026
Owner
KEVIN BARRETT
Owner Address
43 BRIDLE CHASE LN, FORSYTH, GA 31029
Contractor
KEVIN BARRETT
Project Type
ACCESSORY DWELLING
Description
ACCESSORY DWELLING
Technical Details
Construction Type
V-B
Occupancy Group
R-3
Occupant Load
N/A
Square Footage
1564
Zoning
AG
Sprinklers
NO
APN
44042
Limitations
NONE
Inspection History
| Date | Type | Inspector | Result | Notes |
|---|---|---|---|---|
| 06/30/2026 | FINAL | Tyler Adams | PASS | — |
| 06/25/2026 | FINAL | Tyler Adams | CORRECT AND RECALL | - insulate waterlines in crawlspace - direct condensate drains away from foundation - exterior outlets need to be marked WR for wet/damp locations - ac condenser shows a max breaker size at 20 amps, a 30 amp breaker is installed - wire from disconnect to air handler needs to be protected in side of a flexible raceway and secured with connectors - jacket of cable assembly feeding air handler at disconnect needs to extend into the disconnect minimum 1/4 inch and secured by the grommet - junction box cover not secured to bathroom exhaust fan in attic - cables need to be landed in pop in can light junction boxes with a grommet or strain relief connect - |