Date Type Inspector Result Notes
06/30/2026 FINAL Tyler Adams PASS —
06/25/2026 FINAL Tyler Adams CORRECT AND RECALL - insulate waterlines in crawlspace - direct condensate drains away from foundation - exterior outlets need to be marked WR for wet/damp locations - ac condenser shows a max breaker size at 20 amps, a 30 amp breaker is installed - wire from disconnect to air handler needs to be protected in side of a flexible raceway and secured with connectors - jacket of cable assembly feeding air handler at disconnect needs to extend into the disconnect minimum 1/4 inch and secured by the grommet - junction box cover not secured to bathroom exhaust fan in attic - cables need to be landed in pop in can light junction boxes with a grommet or strain relief connect -